Specifications Table for EDLA04-08EV3

EDLA04E2V3 EDLA06E2V3 EDLA08E2V3
Heating capacity Nom. kW 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2)
Power input Heating Power input-=-Heating-=-Nom.-=-kW @ kW 0.840 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2)
COP 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.60 (1), 3.50 (2)
Dimensions Unit Dimensions-=-Unit-=-Height-=-mm @ mm 770 770 770
    Width mm 1250 1250 1250
    Depth mm 362 362 362
Weight Unit kg 88 88 88
Operation range Heating Water side Min. °C 9 (3) 9 (3) 9 (3)
      Max. °C 65 (3) 65 (3) 65 (3)
  Domestic hot water Ambient Min. °CDB -27 -27 -27
      Max. °CDB 35 35 35
    Water side Min. °C 25 25 25
      Max. °C 55 (3) 55 (3) 55 (3)
Sound power level Heating Sound power level-=-Heating-=-Nom.-=-dBA @ dBA 58.0 (1) 60.0 (1) 62.0 (1)
Sound pressure level Heating Nom. dBA 44.0 (1) 47.0 (1) 49.0 (1)
Refrigerant Type   R-32 R-32 R-32
  GWP   675 675 675
  Charge kg 1.35 1.35 1.35
  Charge tCO2Eq 0.91 0.91 0.91
Space heating Average climate water outlet 55°C General Space heating-=-Average climate water outlet 55°C-=-General-=-SCOP @   3.26 3.26 3.32
      Seasonal space heating eff. class   A++ A++ A++
  Average climate water outlet 35°C General Space heating-=-Average climate water outlet 35°C-=-General-=-SCOP @   4.48 4.47 4.56
      Seasonal space heating eff. class   A+++ A+++ A+++
Compressor component Main power supply Phase   3N~ 3N~ 3N~
    Voltage V 220 220 220
Power supply Name   V3 V3 V3
  Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 230 +/-10% 230 +/-10% 230 +/-10%
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing