Specifications Table for EDLA-D3V37

EDLA16DA3V37
Heating capacity Nom. kW 16.0 (2) (1)
Heater capacity Step 1 kW 3
Power input Heating Power input-=-Heating-=-Nom.-=-kW @ kW 3.53 (1), 4.56 (2)
COP 4.53 (1), 3.51 (2)
Dimensions Unit Dimensions-=-Unit-=-Height-=-mm @ mm 870
    Width mm 1380
    Depth mm 460
Weight Unit kg 149
Fan Air flow rate Heating High m³/min 85.0
Operation range Heating Water side Min. °C 15 (6)
      Max. °C 60 (6)
  Domestic hot water Ambient Min. °CDB -25
      Max. °CDB 35
    Water side Min. °C 25
      Max. °C 55 (6)
Refrigerant Type   R-32
  GWP   675
  Charge kg 3.80
  Charge tCO2Eq 2.57
Space heating Average climate water outlet 55°C General Space heating-=-Average climate water outlet 55°C-=-General-=-SCOP @   3.33
      Seasonal space heating eff. class   A++
  Average climate water outlet 35°C General Space heating-=-Average climate water outlet 35°C-=-General-=-SCOP @   4.62
      Seasonal space heating eff. class   A+++
Energy Efficiency Range Space Heating A+++ ~ D, Water Heating A+ ~ F
Compressor component Main power supply Phase   1~
    Voltage V 230
Power supply Name   V3
  Phase   1~
  Frequency Hz 50
  Voltage V 230
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (3) - For more details, see operation range drawing
  (4) - Depends on operation mode, refer to installation manual.