Specifications Table for ERLA11-14DW1

ERLA11D2W1 ERLA11DAW1 ERLA14D2W1 ERLA14DAW1
Dimensions Unit Dimensions-=-Unit-=-Height-=-mm @ mm 870 870 870 870
    Width mm 1100 1100 1100 1100
    Depth mm 460 460 460 460
Weight Unit kg 101 101 101 101
Fan Air flow rate Heating High m³/min 55.8 55.8 70.4 70.4
    Cooling High m³/min 70.4 70.4 85 85
Operation range Cooling Min. °CDB 10 10 10 10
    Max. °CDB 43 43 43 43
  Domestic hot water Min. °CDB -25 -25 -25 -25
    Max. °CDB 25 (1), 35 (1) 25 (1), 35 (1) 25 (1), 35 (1) 25 (1), 35 (1)
Sound power level Heating Sound power level-=-Heating-=-Nom.-=-dBA @ dBA 62.0 (2) 62.0 (2) 62.0 (2) 62.0 (2)
Sound pressure level Heating Nom. dBA 48.0 (2) 48.0 (2) 48.0 (2) 48.0 (2)
Refrigerant Type   R-32 R-32 R-32 R-32
  GWP   675.0 675.0 675.0 675.0
  Charge tCO2Eq 2.57 2.57 2.57 2.57
  Charge kg 3.8 3.8 3.8 3.8
Piping connections Liquid Piping connections-=-Liquid-=-OD-=-mm @ mm 9.5 9.5 9.5 9.5
  Gas OD mm 15.9 15.9 15.9 15.9
  Drain OD mm 26 26 26 26
  Level difference IU - OU Max. m 30.0 30.0 30.0 30.0
  Heat insulation   Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Power supply Name   W1 W1 W1 W1
  Phase   3~ 3~ 3~ 3~
  Frequency Hz 50 50 50 50
  Voltage V 400 400 400 400
Current Recommended fuses A 16 16 16 16
Notes (1) - For more details, see operation range drawing (1) - For more details, see operation range drawing (1) - For more details, see operation range drawing (1) - For more details, see operation range drawing
  (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (2) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.