Specifications Table for 3MXM-N7

3MXM40N2V1B7 3MXM52N2V1B7
Dimensions Unit Height mm 734 734
    Width mm 974 974
    Depth mm 401 401
Weight Unit kg 57 57
Fan motor Speed Cooling Super low rpm 420 420
    Heating Super low rpm 420 420
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor
Sound pressure level Cooling Nom. dBA 46 46
  Heating Nom. dBA 47 47
Refrigerant Type   R-32 R-32
  Charge kg 1.80 1.80
  Charge TCO2Eq 1.22 1.22
  GWP   675 675
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m) 0.02 (for piping length exceeding 30m)
  Level difference IU - OU Max. m 15.0 15.0
    IU - IU Max. m 7.5 7.5
  Total piping length System Actual m 50 (2) 50 (2)
Standard Accessories Installation manual 1 1
  Screw bag 1 1
  Drain plug 1 1
  Reducer assembly 1 1
  Drain cap (1) 6 6
  Drain cap (2) 3 3
Power supply Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 220-240 220-240
Notes (1) - For one room (1) - For one room
  (2) - For combination with CVXM-A, FVXM-A - maximum piping length is 30m. (2) - For combination with CVXM-A, FVXM-A - maximum piping length is 30m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data
  (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases