Specifications Table for 5MXM-N9

5MXM90N2V1B9
Dimensions Unit Height mm 734
    Width mm 974
    Depth mm 401
Weight Unit kg 68.0
Compressor Type   Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10
      Max. °CDB 46
Sound pressure level Cooling Nom. dBA 52.0
  Heating Nom. dBA 52.0
Refrigerant Type   R-32
  Charge kg 2.40
  Charge TCO2Eq 1.62
  GWP   675.0
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m)
  Level difference IU - OU Max. m 15.0
    IU - IU Max. m 7.5
  Total piping length System Actual m 75
Standard Accessories Installation manual 1
  Screw bag 1
  Drain plug 1
  Reducer assembly 1
  Drain cap (1) 6
  Drain cap (2) 3
Power supply Phase   1~
  Frequency Hz 50
  Voltage V 220-240
Notes (1) - For one room
  (2) - See separate drawing for operation range
  (3) - See separate drawing for electrical data
  (4) - Contains fluorinated greenhouse gases