ADEA100A2VEB / AZQS100B8V1B ADEA125A2VEB / AZQS125B8V1B
Indoor unit ADEA100A2VEB ADEA125A2VEB
Outdoor unit AZQS100B8V1B AZQS125B8V1B
Cooling capacity Nom. kW 9.50 12.10
Heating capacity Nom. kW 10.80 13.50
Power input Cooling Nom. kW   5.33
Nominal efficiency EER   2.27
Space cooling Energy efficiency class   A  
  Capacity Pdesign kW 9.50 12.10
  SEER   5.10 4.71
  ηs,c %   185
  Annual energy consumption kWh/a 652 1,543
  A Condition (35°C - 27/19) Pdc kW 9.50 12.10
    EERd   3.21 2.27
    Power input kW 2.96 5.33
  B Condition (30°C - 27/19) Pdc kW 7.00 8.91
    EERd   4.46 3.77
    Power input kW 1.57 2.36
  C Condition (25°C - 27/19) Pdc kW 4.50 5.73
    EERd   6.31 5.53
    Power input kW 0.71 1.04
  D Condition (20°C - 27/19) Pdc kW 3.94 4.88
    EERd   7.78 7.58
    Power input kW 0.51 0.64
Space heating (Average climate) Energy efficiency class   A  
  Capacity Pdesign kW 7.60 7.93
  SCOP/A   3.81 3.50
  SCOPnet/A   3.84 3.51
  ηs,h %   137
  Annual energy consumption kWh/a 2,793 3,167
  Required back up heating cap at design conditions kW 1.83 0.00
  TOL Tol (temperature operating limit) °C -15 -10
    Pdh (declared heating cap) kW 4.18 7.93
    COPd (declared COP)   2.03 2.42
    Power input kW 2.06 3.28
  TBivalent Tbiv (bivalent temperature) °C -7 -10
    Pdh (declared heating cap) kW 6.72 7.93
    COPd (declared COP)   2.84 2.42
    Power input kW 2.37 3.28
  A Condition (-7°C) Pdh (declared heating cap) kW 6.72 7.01
    COPd (declared COP)   2.84 2.63
    Power input kW 2.37 2.67
  B Condition (2°C) Pdh (declared heating cap) kW 4.09 4.49
    COPd (declared COP)   3.94 3.41
    Power input kW 1.04 1.32
  C Condition (7°C) Pdh (declared heating cap) kW 2.82 2.89
    COPd (declared COP)   4.28 4.22
    Power input kW 0.66 0.68
  D Condition (12°C) Pdh (declared heating cap) kW 2.93 3.35
    COPd (declared COP)   5.31 5.18
    Power input kW 0.55 0.65
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000
    Heating PCK kW 0.000 0.015
  Off mode Cooling POFF kW 0.022 0.015
    Heating POFF kW 0.022 0.015
  Standby mode Cooling PSB kW 0.022 0.015
    Heating PSB kW 0.022 0.015
  Thermostat-off mode Cooling PTO kW 0.004 0.000
    Heating PTO kW 0.004 0.015
Indication if the heater is equipped with a supplementary heater (pair application)   No
Supplementary heater (pair application) Back-up capacity Heating elbu kW   0.000
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included No No
Warm season included No No
Ecolabel logo No No
Eurovent Sound power level outdoor Cooling Nom. dBA 70  
  Sound power level indoor Cooling Nom. dBA 58  
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m