Specifications Table for ARXN-NB9

ARXN25N6V1B9 ARXN25N5V1B9 ARXN35N6V1B9 ARXN35N5V1B9 ARXN50NV1B9 ARXN60NV1B9 ARXN25NV1B9 (Archived) ARXN35NV1B9 (Archived)
Dimensions Unit Height mm 550 550 550 550 628 753 550 550
    Width mm 658 658 658 658 855 855 658 658
    Depth mm 289 289 289 289 328 328 289 289
Weight Unit kg 24 24 26 26 37 44 24 26
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB 10 10 10 10 -10 -10 10 10
      Max. °CDB 46 46 46 46 46 46 46 46
  Heating Ambient Min. °CWB -15 -15 -15 -15 -15 -15 -15 -15
      Max. °CWB 18 18 18 18 18 18 18 18
Sound power level Cooling dBA 58 (0.000) 58 60 (0.000) 60 64 65 58 60
Sound pressure level Cooling High dBA 45 45 46 46 51 51 45 46
Refrigerant Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
  Charge kg 0.74 0.74 1.00 1.00 1.45 1.45 0.74 1.00
  Charge TCO2Eq 1.5 1.5 2.1 2.1 3.0 3.0 1.5 2.1
  GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m)        
  Level difference IU - OU Max. m 10.0 10.0 10.0 10.0        
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases
  All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) (2) - All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) (2) - All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) (2) - All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit) (2) - All units are being tested and comply to ISO5151 (non-ducted unit) or ISO13253 (ducted unit)
  All specifications are subjected to change by the manufacturer without prior notice. All specifications are subjected to change by the manufacturer without prior notice. All specifications are subjected to change by the manufacturer without prior notice. All specifications are subjected to change by the manufacturer without prior notice. (3) - All specifications are subjected to change by the manufacturer without prior notice. (3) - All specifications are subjected to change by the manufacturer without prior notice. (3) - All specifications are subjected to change by the manufacturer without prior notice. (3) - All specifications are subjected to change by the manufacturer without prior notice.
Piping connections Additional refrigerant charge kg/m         0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m) 0.02 (for piping length exceeding 7.5m)
  Level difference IU - OU Max. m         10.0 10.0 10.0 10.0