ATXB25C2V1B / ARXB25C2V1B ATXB25C2V1B / ARXB25C5V1B9 ATXB35C2V1B / ARXB35C2V1B ATXB35C2V1B / ARXB35C5V1B9 ATXB50CV1B / ARXB50CV1B ATXB60CV1B / ARXB60CV1B
Indoor unit ATXB25C ATXB25C ATXB35C ATXB35C ATXB50C ATXB60C
Outdoor unit ARXB25C ARXB25C ARXB35C ARXB35C ARXB50C ARXB60C
Cooling capacity Min. kW 1.3 1.3 1.3 1.3 1.630 1.750
  Min. Btu/h 4,400 4,400 4,400 4,400 5,600 6,000
  Min. kcal/h 1,120 1,120 1,120 1,120 1,411.18 1,511.97
  Nom. kW 2.5 (2) 2.5 (2) 3.3 (2) 3.3 (2) 5.480 (2) 6.230 (2)
  Nom. Btu/h 8,500 (2) 8,500 (2) 11,300 (2) 11,300 (2) 18,700 (2) 21,300 (2)
  Nom. kcal/h 2,150 (2) 2,150 (2) 2,840 (2) 2,840 (2) 4,712.3 5,367.51
  Max. kW 3.0 3.0 3.8 3.8 6.200 6.500
  Max. Btu/h 10,200 10,200 13,000 13,000 21,200 22,200
  Max. kcal/h 2,580 2,580 3,270 3,270 5,342.31 5,594.31
Heating capacity Min. kW 1.3 1.3 1.3 1.3 1.170 1.200
  Min. Btu/h 4,400 4,400 4,400 4,400 4,000 4,100
  Min. kcal/h 1,120 1,120 1,120 1,120 1,007.98 1,033.18
  Nom. kW 2.8 (2) 2.8 (2) 3.5 (2) 3.5 (2) 5.620 (2) 6.400 (2)
  Nom. Btu/h 9,600 (2) 9,600 (2) 11,900 (2) 11,900 (2) 19,200 (2) 21,800 (2)
  Nom. kcal/h 2,410 (2) 2,410 (2) 3,010 (2) 3,010 (2) 4,838.32 5,493.51
  Max. kW 4.0 4.0 4.8 4.8 6.600 7.100
  Max. Btu/h 13,600 13,600 16,400 16,400 22,500 24,200.0
  Max. kcal/h 3,440 3,440 4,130 4,130 5,669.9 6,098.3
Power input Cooling Min. kW 0.310 0.310 0.290 0.290 0.280 0.280
    Nom. kW 0.770 (2) 0.770 (2) 1.030 (2) 1.030 (2) 1.700 (2) 1.931 (2)
    Max. kW 1.050 1.050 1.300 1.300 1.910 2.000
  Heating Min. kW 0.250 0.250 0.290 0.290 0.240 0.240
    Nom. kW 0.700 (2) 0.700 (2) 0.940 (2) 0.940 (2) 1.500 (2) 1.680 (2)
    Max. kW 1.110 1.110 1.290 1.290 1.880 2.000
Nominal efficiency EER   3.25 (1) 3.25 (1) 3.21 (1) 3.21 (1) 3.22 (1) 3.23 (1)
  COP   4.01 (1) 4.01 (1) 3.71 (1) 3.71 (1) 3.75 (1) 3.81 (1)
  Annual energy consumption kWh 385 (0.000) 385 (0.000) 514 (0.000) 514 (0.000) 851 (0.000) 964 (0.000)
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Capacity Pdesign kW 2.50 2.50 3.30 3.30 5.48 6.23
  Energy efficiency class   A+ A+ A+ A+ A+ A+
  SEER   5.93 5.93 6.02 6.02 5.93 6.09
  Annual energy consumption kWh/a 148 148 192 192 324 359
  A Condition (35°C - 27/19) Pdc kW 2.50 2.50 3.30 3.30 5.48 6.23
    EERd   3.25 3.25 3.21 3.21 3.19 3.23
    Power input kW 0.77 0.77 1.03 1.03    
  B Condition (30°C - 27/19) Pdc kW 1.84 1.84 2.43 2.43 4.03 4.58
    EERd   5.02 5.02 5.37 5.37 4.98 4.98
    Power input kW 0.37 0.37 0.45 0.45    
  C Condition (25°C - 27/19) Pdc kW 1.22 1.22 1.60 1.60 2.57 2.94
    EERd   7.60 7.60 6.80 6.80 7.07 7.76
    Power input kW 0.16 0.16 0.24 0.24    
  D Condition (20°C - 27/19) Pdc kW 1.15 1.15 1.20 1.20 2.26 2.41
    EERd   9.02 9.02 9.80 9.80 10.38 10.23
    Power input kW 0.13 0.13 0.12 0.12    
Space heating (Average climate) Capacity Pdesign kW 2.40 2.40 2.80 2.80 3.64 3.80
  Energy efficiency class   A+ A+ A+ A+ A+ A+
  SCOP/A   4.01 4.01 4.04 4.04 4.27 4.06
  SCOPnet/A   4.06 4.05 4.09 4.08 4.32 4.12
  Pdh Heating capacity at -10° kW   1.98   2.30    
  Annual energy consumption kWh/a 838 838 970 971 1,195 1,311
  Required back up heating cap at design conditions kW 0.42 0.42 0.50 0.50 0.69 0.72
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -14 -14
    Pdh (declared heating cap) kW 1.72 1.72 1.99 1.99 2.58 2.71
    COPd (declared COP)   2.31 2.31 2.12 2.12 2.43 2.47
    Power input kW 0.74 0.74 0.94 0.94    
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 2.13 2.13 2.48 2.48 3.22 3.36
    COPd (declared COP)   2.41 2.40 2.19 2.19 2.76 2.86
    Power input kW 0.88 0.89 1.13 1.13    
  A Condition (-7°C) Pdh (declared heating cap) kW 2.13 2.13 2.48 2.48 3.22 3.36
    COPd (declared COP)   2.41 2.40 2.19 2.19 2.76 2.86
    Power input kW 0.88 0.89 1.13 1.13    
  B Condition (2°C) Pdh (declared heating cap) kW 1.29 1.29 1.51 1.51 1.92 2.03
    COPd (declared COP)   4.03 4.03 4.19 4.26 4.52 4.31
    Power input kW 0.32 0.32 0.36 0.35    
  C Condition (7°C) Pdh (declared heating cap) kW 0.89 0.89 1.00 1.00 1.33 1.33
    COPd (declared COP)   5.40 5.40 5.46 5.53 5.04 4.60
    Power input kW 0.16 0.16 0.18 0.18    
  D Condition (12°C) Pdh (declared heating cap) kW 1.02 1.02 1.10 1.10 1.58 1.56
    COPd (declared COP)   6.48 6.57 6.69 5.69 6.24 5.63
    Power input kW 0.16 0.16 0.16 0.19    
Space heating (Warm climate) Capacity Pdesignh kW   1.29   1.51    
  Energy efficiency class   A+++   A++    
  SCOP   5.10   4.86    
  SCOPnet   5.34   5.05    
  Annual energy consumption kWh/a   354   435    
  Required back up heating cap at design conditions kW   0.00   0.00    
  TOL Tol (temperature operating limit) °C   -15   -15    
    Pdh (declared heating cap) kW   1.72   1.99    
    COPd (declared COP)   2.31   2.12    
    Power input kW   0.74   0.94    
  TBivalent Tbiv (bivalent temperature) °C   2   2    
    Pdh (declared heating cap) kW   1.29   1.51    
    COPd (declared COP)   4.03   4.26    
    Power input kW   0.32   0.35    
  B Condition (2°C) Pdh (declared heating cap) kW   1.29   1.51    
    COPd (declared COP)   4.03   4.26    
    Power input kW   0.32   0.35    
  C Condition (7°C) Pdh (declared heating cap) kW   0.89   1.00    
    COPd (declared COP)   5.40   5.53    
    Power input kW   0.16   0.18    
  D Condition (12°C) Pdh (declared heating cap) kW   1.02   1.1    
    COPd (declared COP)   6.57   5.69    
    Power input kW   0.16   0.19    
Pto (Thermostat off) W 21.0 21.0 21.0 21.0 28.0 51.6
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0 0.0 0.0 0.0 0.0
  Off mode POFF W 1.0 1.0 1.0 1.0 6.4 6.4
  Standby mode Cooling PSB W 2.0 2.0 2.0 2.0 6.4 6.4
    Heating PSB W 2.0 2.0 2.0 2.0 6.4 6.4
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25    
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25    
Cooling function included Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No
Warm season included No No No No No No
Ecolabel logo         No No
Eurovent Sound power level outdoor Cooling Nom. dBA   60   62    
  Sound power level indoor Cooling Nom. dBA   55   58    
Piping connections Drain OD mm 18 18 18 18    
  Gas OD mm 9.5 9.5 9.5 9.5    
  Heat insulation   Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes    
  Liquid OD mm 6.35 6.35 6.35 6.35    
Power factor Nominal Cooling %   85.8 (0.000)   81.9 (0.000)    
    Heating %   93.8 (0.000)   86.0 (0.000)    
Current Nominal running current (RLA) - 50Hz Cooling A 3.82 3.82 5.5 5.5 7.51 8.52
    Heating A 3.2 3.2 4.7 4.7 6.65 7.46
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
    Contains fluorinated greenhouse gases   Contains fluorinated greenhouse gases