AZQS100B7Y1B UK AZQS125B7Y1B UK AZQS140B7Y1B UK
Sound pressure level Heating Nom. dBA 57 58 54
  Cooling Nom. dBA 53 54 53
  Night quiet mode Level 1 dBA 49 49 49
Standard Accessories Tie-wraps 2 2 2
  Installation manual 1 1 1
Refrigerant Circuits Quantity 1 1 1
  Charge TCO2Eq 6.1 6.1 8.4
  Charge kg 2.9 2.9 4.0
  Refrigerant-=-Gwp Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type)
Fan motor Output W 200 200 94
  Quantity Brushless DC motor Brushless DC motor Brushless DC motor
Operation range Cooling Ambient Max. °CDB 46 46 46
      Min. °CDB -5 -5 -5
  Heating Ambient Max. °CWB 15.5 15.5 15.5
      Min. °CWB -15 -15 -15
Heat exchanger Fin Treatment WF fin WF fin WF fin
Piping connections Piping length OU - IU Min. m 5 (7) 5 (7) 5 (7)
      Max. m 30 (7) 30 (7) 30 (7)
    System Chargeless m 30 30 30
      Equivalent m 40 40 40
  Liquid OD mm 9.52 9.52 9.52
    Quantity Flare connection Flare connection Flare connection
  Gas OD mm 15.9 15.9 15.9
    Quantity Flare connection Flare connection Flare connection
  Drain OD mm 26 26 26
    Quantity Hole Hole Hole
  Level difference IU - IU Max. m 0.5 0.5 0.5
    IU - OU Max. m 30.0 30.0 30.0
  Additional refrigerant charge kg/m See installation manual See installation manual See installation manual
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Sound power level Cooling dBA 70 71 70
Safety devices Item 01 Fuse Fuse Fuse
Dimensions Packed unit Width mm 1,015 1,015 1,015
    Height mm 1,170 1,170 1,610
    Depth mm 422 422 422
  Unit Width mm 940 940 940
    Depth mm 320 320 320
    Height mm 990 990 1,430
Compressor Quantity Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Casing Colour Painted galvanized steel plate Painted galvanized steel plate Painted galvanized steel plate
Capacity control Method Inverter controlled Inverter controlled Inverter controlled
Weight Packed unit kg 88 88 108
  Unit kg 82 82 101
Fan Air flow rate Heating Nom. m³/min 83 83 62
    Cooling Nom. m³/min 76 77 83
  Quantity Horizontal Horizontal Horizontal
Refrigerant oil Charged volume l 0.9 0.9 1.35
  Type FVC50K FVC50K FVC50K
Defrost control Reversed cycle Reversed cycle Reversed cycle
Wiring connections For connection with indoor Remark See installation manual outdoor unit See installation manual outdoor unit See installation manual outdoor unit
  For power supply Remark See installation manual outdoor unit See installation manual outdoor unit See installation manual outdoor unit
Power supply Voltage range Max. % 10 10 10
    Min. % -10 -10 -10
  Frequency Hz 50 50 50
  Voltage V 380-415 380-415 380-415
  Phase 3N~ 3N~ 3N~
Current Zmax List Complies to EN61000-3-11 Complies to EN61000-3-11 Complies to EN61000-3-11
  Recommended fuses A 20 20 25
Notes PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
  See separate drawing for electrical data See separate drawing for electrical data See separate drawing for electrical data
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases
  Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  For details regarding your combination of oudoor and indoor unit, refer to the technical databook For details regarding your combination of oudoor and indoor unit, refer to the technical databook For details regarding your combination of oudoor and indoor unit, refer to the technical databook
Power supply intake Outdoor unit only Outdoor unit only Outdoor unit only