Specifications Table for EABX-D6V / EPGA011-016DV

EABX16DA6V / EPGA11DAV3 EABX16DA6V / EPGA14DAV3 EABX16DA6V / EPGA16DAV3
Indoor unit EABX16DA6V EABX16DA6V EABX16DA6V
Heating capacity Nom. kW 11.1 (1), 11.3 (2) 14.5 (1), 14.5 (2) 16.5 (1), 15.6 (2)
Cooling capacity Nom. kW 10.5 (1), 10.7 (2) 11.1 (1), 11.9 (2) 13.5 (1), 11.9 (2)
Power input Heating Nom. kW 2.16 (1), 2.91 (2) 2.91 (1), 3.96 (2) 3.45 (1), 4.21 (2)
  Cooling Nom. kW 2.21 (1), 3.30 (2) 2.72 (1), 3.97 (2) 3.42 (1), 3.97 (2)
COP 5.15 (1), 3.88 (2) 4.99 (1), 3.65 (2) 4.78 (1), 3.71 (2)
EER 4.75 (1), 3.23 (2) 4.09 (1), 2.99 (2) 3.94 (1), 2.99 (2)
Space heating Average climate water outlet 55°C General SCOP   3.32 3.37 3.43
      Seasonal space heating eff. class   A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.44 4.51 4.61
      Seasonal space heating eff. class   A+++ A+++ A+++
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )