EHBH11CB3V / ERHQ011BAW1 EHBH11CB9W / ERHQ011BAW1 EHBH16CB3V / ERHQ014BAW1 EHBH16CB9W / ERHQ014BAW1 EHBH16CB9W / ERHQ016BAW1 EHBH16CB3V / ERHQ016BAW1
Space heating general Air to water unit Rated airflow (outdoor) m³/h 5,400 5,400 5,400 5,400 5,400 5,400
  Other Psb (Standby mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Off mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Thermostat off) kW 0.057 0.057 0.057 0.057 0.057 0.057
    Pck (Crankcase heater mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Cdh (Degradation heating) 1.00 1.00 1.00 1.00 1.00 1.00
  Integrated supplementary heater Psup kW 3.00 9.00 3.00 9.00 9.00 3.00
    NOx emission mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00
    Type of energy input Electrical Electrical Electrical Electrical Electrical Electrical
Water side Heat exchanger Water flow rate Heating Nom. l/min 32.5 (5), 31.5 (6) 32.5 (5), 31.5 (6) 41.6 (5), 38.9 (6) 41.6 (5), 38.9 (6) 46.0 (5), 43.3 (6) 46.0 (5), 43.3 (6)
Pump Nominal ESP unit Heating kPa 36.0 (5), 39.0 (6) 36.0 (5), 39.0 (6) 49.0 (5), 57.0 (6) 49.0 (5), 57.0 (6) 32.0 (5), 43.0 (6) 32.0 (5), 43.0 (6)
Space heating Cold climate water outlet 55°C General Prated at -22°C kW 10.4 10.4 11.9 11.9 13.6 13.6
      Annual energy consumption kWh 10,400 10,400 11,500 11,500 12,400 12,400
      Ƞs (Seasonal space heating efficiency) % 93.0 93.0 96.8 96.8 103 103
      Qhe Annual energy consumption (GCV) Gj 37.4 37.4 41.3 41.3 44.6 44.6
  Average climate water outlet 35°C A Condition (-7°CDB/-8°CWB) PERd % 109 109 109 109 105 105
      Pdh kW 6.64 6.64 8.59 8.59 9.24 9.24
      COPd 2.72 2.72 2.73 2.73 2.63 2.63
    C Condition (7°CDB/6°CWB) Pdh kW 3.92 3.92 5.02 5.02 5.56 5.56
      PERd % 137 137 180 180 193 193
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    D Condition (12°CDB/11°CWB) Pdh kW 4.10 4.10 5.02 5.02 5.42 5.42
      PERd % 136 136 184 184 197 197
      COPd 1.00 1.00 0.950 0.950 0.950 0.950
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 5.22 5.22 6.53 6.53 7.45 7.45
    General Annual energy consumption kWh 7,160 7,160 8,530 8,530 9,530 9,530
      Ƞs (Seasonal space heating efficiency) % 120 120 131 131 130 130
      Prated at -10°C kW 11.3 11.3 14.5 14.5 16.1 16.1
      Qhe Annual energy consumption (GCV) Gj 25.8 25.8 30.7 30.7 34.3 34.3
      Seasonal space heating eff. class 3.08 3.08 3.34 3.34 3.33 3.33
    B Condition (2°CDB/1°CWB) Pdh kW 6.10 6.10 7.81 7.81 8.64 8.64
      PERd % 160 160 160 160 153 153
      COPd 1.00 1.00 1.00 1.00 3.82 3.82
    Tbiv (bivalent temperature) Pdh kW 7.63 7.63 9.60 9.60 10.2 10.2
      PERd % 132 132 136 136 130 130
      Tbiv °C -2.00 -2.00 -1.00 -1.00 -1.00 -1.00
      COPd 3.31 3.31 3.39 3.39 3.26 3.26
    Tol (temperature operating limit) PERd % 98.8 98.8 100 100 97.2 97.2
      WTOL °C 35.0 35.0 35.0 35.0 35.0 35.0
      Pdh kW 6.10 6.10 7.97 7.97 8.60 8.60
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      COPd 2.47 2.47 2.51 2.51 2.43 2.43
  Warm climate water outlet 55°C General Prated at 2°C kW 7.14 7.14 8.84 8.84 9.33 9.33
      Ƞs (Seasonal space heating efficiency) % 114 114 124 124 124 124
      Annual energy consumption kWh 2,730 2,730 3,180 3,180 3,410 3,410
      Qhe Annual energy consumption (GCV) Gj 9.81 9.81 11.5 11.5 12.3 12.3
  Cold climate water outlet 35°C General Qhe Annual energy consumption (GCV) Gj 32.4 32.4 36.4 36.4 41.8 41.8
      Annual energy consumption kWh 9,010 9,010 10,100 10,100 11,600 11,600
      Ƞs (Seasonal space heating efficiency) % 108 108 126 126 127 127
      Prated at -22°C kW 10.5 10.5 13.6 13.6 15.7 15.7
  Warm climate water outlet 35°C General Prated at 2°C kW 8.20 8.20 10.1 10.1 10.7 10.7
      Ƞs (Seasonal space heating efficiency) % 127 127 156 156 160 160
      Qhe Annual energy consumption (GCV) Gj 10.2 10.2 10.3 10.3 10.7 10.7
      Annual energy consumption kWh 2,840 2,840 2,860 2,860 2,980 2,980
  Average climate water outlet 55°C A Condition (-7°CDB/-8°CWB) PERd % 84.0 84.0 78.0 78.0 78.0 78.0
      Pdh kW 7.30 7.30 8.34 8.34 8.62 8.62
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalent temperature) Tbiv °C -3.00 -3.00 -3.00 -3.00 -3.00 -3.00
      Pdh kW 7.12 7.12 9.02 9.02 10.0 10.0
      PERd % 96.0 96.0 95.2 95.2 94.4 94.4
      COPd 2.40 2.40 2.38 2.38 2.36 2.36
    Tol (temperature operating limit) TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Pdh kW 3.64 3.64 6.21 6.21 6.10 6.10
      PERd % 40.0 40.0 56.4 56.4 50.8 50.8
      WTOL °C 55.0 55.0 55.0 55.0 55.0 55.0
      COPd 1.00 1.00 1.41 1.41 1.27 1.27
    General Ƞs (Seasonal space heating efficiency) % 113 113 109 109 115 115
      Qhe Annual energy consumption (GCV) Gj 24.1 24.1 32.2 32.2 33.0 33.0
      Annual energy consumption kWh 6,680 6,680 8,960 8,960 9,160 9,160
      Prated at -10°C kW 9.99 9.99 12.7 12.7 13.7 13.7
      Seasonal space heating eff. class 2.90 2.90 2.80 2.80 2.96 2.96
    B Condition (2°CDB/1°CWB) Pdh kW 5.33 5.33 6.60 6.60 7.50 7.50
      PERd % 132 132 121 121 125 125
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    C Condition (7°CDB/6°CWB) Pdh kW 4.42 4.42 4.48 4.48 4.90 4.90
      PERd % 157 157 168 168 178 178
      COPd 0.950 0.950 1.00 1.00 0.950 0.950
    D Condition (12°CDB/11°CWB) PERd % 221 221 259 259 225 225
      Pdh kW 5.30 5.30 5.42 5.42 5.30 5.30
      COPd 0.940 0.940 0.930 0.930 0.940 0.940
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 6.35 6.35 6.52 6.52 7.62 7.62
Heating capacity Nom. kW 11.3 (1), 11.0 (2) 11.3 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.1 (1), 15.1 (2) 16.1 (1), 15.1 (2)
General LW(A) Sound power level (according to EN14825) Indoor dB(A) 41.0 41.0 44.0 44.0 44.0 44.0
  Supplier/Manufacturer details Name and address Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Low-temperature heat pump No No No No No No
LW(A) Sound power level (according to EN14825) Outdoor dB(A) 64.0 64.0 64.0 64.0 66.0 66.0
Power input Heating Nom. kW 2.63 (1), 3.24 (2) 2.63 (1), 3.24 (2) 3.42 (1), 4.21 (2) 3.42 (1), 4.21 (2) 3.82 (1), 4.69 (2) 3.82 (1), 4.69 (2)
Sound condition Ecodesign and energy label 4.30 (1), 3.39 (2) 4.30 (1), 3.39 (2) 4.24 (1), 3.22 (2) 4.24 (1), 3.22 (2) 4.20 (1), 3.22 (2) 4.20 (1), 3.22 (2)
Notes Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C)
  Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)