EHBX04CB3V / ERLQ004CAV3 EHBX08CB3V / ERLQ006CAV3 EHBX08CB9W / ERLQ006CAV3 EHBX08CB9W / ERLQ008CAV3 EHBX08CB3V / ERLQ008CAV3 EHBX11CB9W / ERLQ011CAV3 EHBX11CB3V / ERLQ011CAV3 EHBX16CB3V / ERLQ014CAV3 EHBX16CB9W / ERLQ014CAV3 EHBX16CB9W / ERLQ016CAV3 EHBX16CB3V / ERLQ016CAV3
Heating capacity Min. kW 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)            
  Nom. kW 4.40 (1), 4.03 (2) 6.00 (1), 5.67 (2) 6.00 (1), 5.67 (2) 7.40 (1), 6.89 (2) 7.40 (1), 6.89 (2) 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Max. kW 5.12 (1), 4.90 (2) 8.35 (1), 7.95 (2) 8.35 (1), 7.95 (2) 10.0 (1), 9.53 (2) 10.0 (1), 9.53 (2) 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
Cooling capacity Min. kW 2.00 (1), 2.00 (2) 2.50 (1), 2.50 (2) 2.50 (1), 2.50 (2) 2.50 (1), 2.50 (2) 2.50 (1), 2.50 (2)            
  Nom. kW 4.08 (1), 4.17 (2) 5.88 (1), 4.84 (2) 5.88 (1), 4.84 (2) 6.20 (1), 5.36 (2) 6.20 (1), 5.36 (2) 12.1 (1), 11.7 (2) 12.1 (1), 11.7 (2) 12.7 (1), 12.6 (2) 12.7 (1), 12.6 (2) 13.8 (1), 13.1 (2) 13.8 (1), 13.1 (2)
Power input Heating Nom. kW 0.870 (1), 1.13 (2) 1.27 (1), 1.59 (2) 1.27 (1), 1.59 (2) 1.66 (1), 2.01 (2) 1.66 (1), 2.01 (2) 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
    Max. kW           3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
  Cooling Nom. kW 0.900 (1), 1.80 (2) 1.51 (1), 2.07 (2) 1.51 (1), 2.07 (2) 1.64 (1), 2.34 (2) 1.64 (1), 2.34 (2) 3.05 (1), 4.31 (2) 3.05 (1), 4.31 (2) 3.21 (1), 5.08 (2) 3.21 (1), 5.08 (2) 3.74 (1), 5.73 (2) 3.74 (1), 5.73 (2)
COP 5.04 (1), 3.58 (2) 4.74 (1), 3.56 (2) 4.74 (1), 3.56 (2) 4.45 (1), 3.42 (2) 4.45 (1), 3.42 (2)            
EER 4.55 (1), 2.32 (2) 3.89 (1), 2.34 (2) 3.89 (1), 2.34 (2) 3.79 (1), 2.29 (2) 3.79 (1), 2.29 (2)            
Pump Nominal ESP unit Cooling kPa           33.0 (5), 3.00 (6) 33.0 (5), 3.00 (6) 64.0 (5), 32.0 (6) 64.0 (5), 32.0 (6) 61.0 (5), 23.0 (6) 61.0 (5), 23.0 (6)
    Heating kPa           37.0 (7), 39.0 (8) 37.0 (7), 39.0 (8) 49.0 (7), 57.0 (8) 49.0 (7), 57.0 (8) 33.0 (7), 42.0 (8) 33.0 (7), 42.0 (8)
Water side Heat exchanger Water flow rate Cooling Nom. l/min           33.6 (5), 43.1 (6) 33.6 (5), 43.1 (6) 36.0 (5), 46.0 (6) 36.0 (5), 46.0 (6) 37.6 (5), 48.0 (6) 37.6 (5), 48.0 (6)
    Heating Nom. l/min           32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
General LW(A) Sound power level (according to EN14825) Indoor dB(A)           41.0 41.0 44.0 44.0 44.0 44.0
LW(A) Sound power level (according to EN14825) Outdoor dB(A)           64.0 64.0 64.0 64.0 66.0 66.0
Space heating general Air to water unit Rated airflow (outdoor) m³/h           5,400 5,400 5,400 5,400 5,400 5,400
  Other Pck (Crankcase heater mode) kW           0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Off mode) kW           0.055 0.055 0.055 0.055 0.055 0.055
    Psb (Standby mode) kW           0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Thermostat off) kW           0.057 0.057 0.057 0.057 0.057 0.057
  Integrated supplementary heater NOx emission mg/kWh           0.00 0.00 0.00 0.00 0.00 0.00
    Psup kW           9.00 3.00 3.00 9.00 9.00 3.00
Space heating Average climate water outlet 55°C General SCOP   3.20 3.22 3.22 3.20 3.20            
      Annual energy consumption kWh           6,260 6,260 7,900 7,900 8,970 8,970
      Ƞs (Seasonal space heating efficiency) %           120 120 123 123 119 119
      Prated at -10°C kW           9.99 9.99 12.7 12.7 13.9 13.9
      Qhe Annual energy consumption (GCV) Gj           22.6 22.6 28.4 28.4 32.3 32.3
      Seasonal space heating eff. class   A++ A++ A++ A++ A++            
    A Condition (-7°CDB/-8°CWB) Pdh kW           8.83 8.83 9.97 9.97 12.2 12.2
      PERd %           79.6 79.6 70.4 70.4 71.2 71.2
    B Condition (2°CDB/1°CWB) Pdh kW           5.28 5.28 6.76 6.76 7.61 7.61
      PERd %           130 130 142 142 125 125
    C Condition (7°CDB/6°CWB) Pdh kW           4.47 4.47 4.66 4.66 4.83 4.83
      PERd %           172 172 169 169 176 176
    D Condition (12°CDB/11°CWB) Pdh kW           5.37 5.37 5.26 5.26 5.38 5.38
      PERd %           256 256 218 218 254 254
    Tol (temperature operating limit) Pdh kW           9.08 9.08 12.2 12.2 13.3 13.3
      PERd %           71.6 71.6 70.0 70.0 68.4 68.4
      TOL °C           -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      WTOL °C           55.0 55.0 55.0 55.0 55.0 55.0
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW           0.910 0.910 0.550 0.550 0.580 0.580
    Tbiv (bivalent temperature) Pdh kW           8.83 8.83 11.0 11.0 12.2 12.2
      PERd %           79.6 79.6 76.8 76.8 71.2 71.2
      Tbiv °C           -7.00 -7.00 -6.00 -6.00 -7.00 -7.00
  Cold climate water outlet 55°C General Annual energy consumption kWh           6,740 6,740 7,870 7,870 8,580 8,580
      Ƞs (Seasonal space heating efficiency) %           95.0 95.0 95.5 95.5 98.3 98.3
      Prated at -22°C kW           6.99 6.99 8.15 8.15 9.12 9.12
      Qhe Annual energy consumption (GCV) Gj           24.3 24.3 28.3 28.3 30.9 30.9
  Warm climate water outlet 55°C General Annual energy consumption kWh           2,630 2,630 3,270 3,270 3,420 3,420
      Ƞs (Seasonal space heating efficiency) %           125 125 135 135 136 136
      Prated at 2°C kW           7.58 7.58 9.84 9.84 10.3 10.3
      Qhe Annual energy consumption (GCV) Gj           9.47 9.47 11.8 11.8 12.3 12.3
  Average climate water outlet 35°C General SCOP   4.52 4.29 4.29 4.34 4.34            
      Annual energy consumption kWh           5,380 5,380 7,250 7,250 8,270 8,270
      Ƞs (Seasonal space heating efficiency) %           156 156 153 153 149 149
      Prated at -10°C kW           11.2 11.2 14.5 14.5 16.0 16.0
      Qhe Annual energy consumption (GCV) Gj           19.4 19.4 26.1 26.1 29.8 29.8
      Seasonal space heating eff. class   A++ A++ A++ A++ A++            
    A Condition (-7°CDB/-8°CWB) Pdh kW           8.88 8.88 10.7 10.7 12.4 12.4
      PERd %           105 105 105 105 93.2 93.2
    B Condition (2°CDB/1°CWB) Pdh kW           6.03 6.03 7.71 7.71 8.62 8.62
      PERd %           162 162 163 163 150 150
    C Condition (7°CDB/6°CWB) Pdh kW           5.74 5.74 5.05 5.05 5.74 5.74
      PERd %           271 271 228 228 271 271
    D Condition (12°CDB/11°CWB) Pdh kW           6.50 6.50 5.16 5.16 6.50 6.50
      PERd %           359 359 268 268 359 359
    Tol (temperature operating limit) Pdh kW           8.76 8.76 12.6 12.6 11.7 11.7
      PERd %           93.6 93.6 104 104 82.0 82.0
      TOL °C           -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      WTOL °C           35.0 35.0 35.0 35.0 35.0 35.0
    Tbiv (bivalent temperature) Pdh kW           9.09 9.09 11.6 11.6 12.1 12.1
      PERd %           113 113 113 113 102 102
      Tbiv °C           -5.00 -5.00 -5.00 -5.00 -4.00 -4.00
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW           2.44 2.44 1.93 1.93 4.35 4.35
  Cold climate water outlet 35°C General Annual energy consumption kWh           6,430 6,430 8,170 8,170 9,050 9,050
      Ƞs (Seasonal space heating efficiency) %           148 148 141 141 137 137
      Prated at -22°C kW           10.3 10.3 12.3 12.3 13.3 13.3
      Qhe Annual energy consumption (GCV) Gj           23.1 23.1 29.4 29.4 32.6 32.6
  Warm climate water outlet 35°C General Annual energy consumption kWh           1,950 1,950 2,350 2,350 2,480 2,480
      Ƞs (Seasonal space heating efficiency) %           192 192 199 199 199 199
      Prated at 2°C kW           9.06 9.06 10.9 10.9 11.4 11.4
      Qhe Annual energy consumption (GCV) Gj           7.02 7.02 8.46 8.46 8.92 8.92
Notes Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
  Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
  DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C)
Space heating general Other Capacity control           1.00 1.00 1.00 1.00 1.00 1.00
  Integrated supplementary heater Type of energy input           Electrical Electrical Electrical Electrical Electrical Electrical
Space heating Average climate water outlet 35°C A Condition (-7°CDB/-8°CWB) COPd           2.63 2.63 2.63 2.63 2.33 2.33
    C Condition (7°CDB/6°CWB) COPd           0.940 0.940 1.00 1.00 0.940 0.940
    D Condition (12°CDB/11°CWB) COPd           0.920 0.920 0.930 0.930 0.920 0.920
    General Seasonal space heating eff. class           3.98 3.98 3.90 3.90 3.80 3.80
    B Condition (2°CDB/1°CWB) COPd           1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalent temperature) COPd           2.82 2.82 2.83 2.83 2.56 2.56
    Tol (temperature operating limit) COPd           2.34 2.34 2.60 2.60 2.05 2.05
  Average climate water outlet 55°C A Condition (-7°CDB/-8°CWB) COPd           1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalent temperature) COPd           1.99 1.99 1.92 1.92 1.78 1.78
    Tol (temperature operating limit) COPd           1.79 1.79 1.75 1.75 1.71 1.71
    General Seasonal space heating eff. class           3.09 3.09 3.16 3.16 3.06 3.06
    B Condition (2°CDB/1°CWB) COPd           1.00 1.00 1.00 1.00 1.00 1.00
    C Condition (7°CDB/6°CWB) COPd           0.950 0.950 0.950 0.950 1.00 1.00
    D Condition (12°CDB/11°CWB) COPd           0.930 0.930 0.940 0.940 0.930 0.930
General Supplier/Manufacturer details Name and address           Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Low-temperature heat pump           No No No No No No
Sound condition Ecodesign and energy label           3.98 (1), 2.72 (2) 3.98 (1), 2.72 (2) 3.96 (1), 2.47 (2) 3.96 (1), 2.47 (2) 3.69 (1), 2.29 (2) 3.69 (1), 2.29 (2)
Notes           DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
            DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)