EHYHBH05AAV32 EHYHBH08AAV32
Casing Colour   White White
  Material   Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 902 902
    Width mm 450 450
    Depth mm 164 164
Weight Unit kg 30.0 31.2
PED Category   Art3§3, Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC Category I
Water side Heat exchanger Water flow rate Heating Max. l/min 23.0 (7.000) 23.5 (7.000)
Operation range Heating Water side Min. °C 25 (8) 25 (8)
      Max. °C 55 (8) 55 (8)
Power supply Name   V3 V3
  Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 230 230
Wiring connections For connection with user interface Quantity   2 2
    Remark   0.75 mm² till 1,25 mm² (max length 500m) 0.75 mm² till 1,25 mm² (max length 500m)
Notes Only for indoor unit Only for indoor unit
  DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed
  DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed
  Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed
  Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed
  Min. required Min. required
  Boiler bypassed Boiler bypassed
  For operation range of *HYHB* and *HYKOMB33AA, see operation range drawing For operation range of *HYHB* and *HYKOMB33AA, see operation range drawing