EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV400 EKEXV500 EKEXV250
Connection ratio Outdoor units with only ventilation units connected Minimum % 50 50 50 50 50 50 50 50 50 50
      Maximum % 110 110 110 110 110 110 110 110 110 110
  Ventilation units when combined with VRV® indoor units Maximum % 30 30 30 30 30 30 30 30 30 30
Dimensions Unit Height mm 401 401 401 401 401 401 401 401 401 401
    Width mm 215 215 215 215 215 215 215 215 215 215
    Depth mm 78 78 78 78 78 78 78 78 78 78
  Packed unit Height mm 457 457 457 457 457 457 457 457 457 457
    Width mm 270 270 270 270 270 270 270 270 270 270
    Depth mm 120 120 120 120 120 120 120 120 120 120
Weight Unit kg 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
  Packed unit kg 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Packing Material   Carton Carton Carton Carton Carton Carton Carton Carton Carton Carton
  Weight kg 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29
Packing 2 Material   EPS EPS EPS EPS EPS EPS EPS EPS EPS EPS
  Weight kg 0.066 0.066 0.066 0.066 0.066 0.066 0.066 0.066 0.066 0.066
Casing Colour   Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white Ivory white
  Material   Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal
Operation range Cooling Min. °CDB -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0
    Max. °CDB 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0
  On coil temperature Heating Min. °CDB 10 (6) 10 (6) 10 (6) 10 (6) 10 (6) 10 (6) 10 (6) 10 (6) 10 (6) 10 (6)
    Cooling Max. °CDB 35 (7) 35 (7) 35 (7) 35 (7) 35 (7) 35 (7) 35 (7) 35 (7) 35 (7) 35 (7)
Sound pressure level Nom. dBA 45 45 45 45 45 45 45 45 45 45
Piping connections Liquid Type   Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection
    OD mm 6.35 9.52 9.52 9.52 9.52 9.52 9.52 12.7 15.9 9.52
  Gas Type   Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection
    OD mm 6.35 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
  Piping length OU - IU Min. m 0 (2) 0 (2) 0 (2) 0 (2) 0 (2) 0 (2) 0 (2) 0 (2) 0 (2) 0 (2)
      Max. m 5 5 5 5 5 5 5 5 5 5
    System Chargeless m 0 0 0 0 0 0 0 0 0 0
  Level difference IU - IU Max.   See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit See manual, depends on the outdoor unit
  Heat insulation   Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet Both inlet and outlet
Notes The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor. The sound pressure value is the maximum value measured at 10cm from the motor.
  Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit
  Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit Maximum installation height difference: See manual; depends on outdoor unit