EKHVMYD50ABV1 EKHVMYD80ABV1
Cooling capacity Nom. kW 5.0 (1) 8.0 (1)
Heating capacity Nom. kW 5.60 (2) 9.00 (2)
Casing Colour   Metallic grey Metallic grey
  Material   Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 705 705
    Width mm 600 600
    Depth mm 695 695
  Packed unit Height mm 860 860
    Width mm 680 680
    Depth mm 800 800
Weight Unit kg 120 120
  Packed unit kg 135 135
Packing Material   EPS, Cardboard, MDF, Wood (pallet), Metal EPS, Cardboard, MDF, Wood (pallet), Metal
  Weight kg 9 9
Refrigerant side heat exchanger Type   Plate heat exchanger Plate heat exchanger
  Quantity   1 1
  Plates Quantity   66 66
  Material   AISI 316 AISI 316
  Insulation material   Felt type Felt type
Pump Type   DC motor DC motor
  Nr of speeds   Inverter controlled Inverter controlled
  Nominal ESP unit Heating kPa 84.9 (3) 69.2 (3)
Water side Heat exchanger Water flow rate Min. l/min 5.0 5.0
    Heating Nom. l/min 16.1 (3) 25.8 (3)
    Cooling Nom. l/min 14.3 (3) 22.9 (3)
  Heating Type   Plate heat exchanger Plate heat exchanger
    Quantity   1 1
    Plates Quantity   72 72
    Material   AISI 316 AISI 316
    Water volume l 2.2 2.2
    Insulation material   Felt type Felt type
  Cooling Type   Plate heat exchanger Plate heat exchanger
    Quantity   1 1
    Plates Quantity   42 42
    Material   AISI 316 AISI 316
    Water volume l 0.8 0.8
    Insulation material   EPDM type EPDM type
Expansion vessel Heating Volume l 7 7
  Cooling Volume l 2 2
  Max. water pressure bar 3 3
  Pre pressure bar 1 1
Water filter Diameter perforations mm 1.0 1.0
  Material   Brass Brass
Cascade compressor Quantity   1 1
  Motor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor
    Starting method   Inverter compressor Inverter compressor
Water circuit Piping connections diameter inch G 1" (female) G 1" (female)
  Piping inch 1" 1"
  Safety valve bar 3 3
  Manometer   Yes Yes
  Drain valve / fill valve   Yes Yes
  Shut off valve   Yes Yes
  Air purge valve   Yes Yes
  Heating water system Water volume Max. l 200 200
      Min. l 20 20
Refrigerant Type   R-134a R-134a
  Charge kg 2.0 2.0
Refrigerant circuit Gas side diameter mm 12.7 12.7
  Suction side diameter mm 15.9 15.9
  Liquid side diameter mm 9.5 9.5
  High pressure side Design pressure bar 38 38
Refrigerant oil Charged volume l 0.75 0.75
  Type   FVC50K FVC50K
Sound pressure level Nom. dBA 40 (4), 43 (5), 0 (6), 0 (7) 42 (4), 43 (5), 0 (6), 0 (7)
  Night quiet mode Level 1 dBA 38 (4), 0 (7), 0 (6) 38 (4), 0 (7), 0 (6)
Operation range Heating Ambient Min. °C -15 -15
      Max. °C 20 20
    Water side Min. °C 25 (8) 25 (8)
      Max. °C 80 (8) 80 (8)
  Cooling Ambient Min. °CDB 10 10
      Max. °CDB 43 43
    Water side Min. °C 5 (7) 5 (7)
      Max. °C 20 (7) 20 (7)
  Domestic hot water Ambient Min. °CDB -15 -15
      Max. °CDB 35 35
    Water side Min. °C 45 (8) 45 (8)
      Max. °C 75 (8) 75 (8)
Installation place Indoor Indoor
Power supply Name   V1 V1
  Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 220-240 220-240
  Voltage range Min. % -10 -10
    Max. % 6 6
Current Zmax Text Ω 0.46, See note 9, See note 10, See note 11 0.46, See note 9, See note 10, See note 11
  Minimum Ssc value kVa 1459, See note 12 1459, See note 12
  Maximum running current Cooling A 16.5 16.5
    Heating A 16.5 16.5
  Recommended fuses A 20 20
Multi tenant Power supply Voltage V 24 24
    Voltage range Min. % -20 -20
      Max. % 20 20
  Current Maximum running current A 1 1
    Recommended fuses A 3.15 3.15
Wiring connections For power supply Quantity   2G 2G
    Type of wires   Select diameter and type according to national and local regulations Select diameter and type according to national and local regulations
  Benefit kWh rate power supply installations Quantity   2G+2G 2G+2G
    Type of wires   Select diameter and type according to national and local regulations Select diameter and type according to national and local regulations
  For power supply multi tenant Quantity   2G 2G
    Remark   Select diameter and type according to national and local regulations Select diameter and type according to national and local regulations
  For connection with outdoor unit Quantity   2 2
    Remark   F1 + F2 F1 + F2
Power supply intake Both indoor and outdoor unit Both indoor and outdoor unit
Notes Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  EW 40°C; LW 45°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB EW 40°C; LW 45°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB
  For water Dt 5°C For water Dt 5°C
  Sound levels are measured at: EW 55°C; LW 65°C Sound levels are measured at: EW 55°C; LW 65°C
  Sound levels are measured at: EW 70°C; LW 80°C Sound levels are measured at: EW 70°C; LW 80°C
  Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections.
  EW = entering water temperature - LW = leaving water temperature EW = entering water temperature - LW = leaving water temperature
  See separate drawing for operation range See separate drawing for operation range
  In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
  European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A. European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
  Zsys: system impedance Zsys: system impedance
  Short-circuit power Short-circuit power