EVLQ05CAV3 EVLQ08CAV3
Casing Colour   Ivory white Ivory white
  Material   Polyester painted galvanised steel plate Polyester painted galvanised steel plate
Dimensions Unit Height mm 735 735
    Width mm 832 832
    Depth mm 307 307
  Packed unit Height mm 797 797
    Width mm 990 990
    Depth mm 390 390
Weight Unit kg 54 56
  Packed unit kg 57 59
Packing Material   EPS, Carton EPS, Carton
  Weight kg 3 3
Heat exchanger Length mm 845 845
  Rows Quantity   2 2
  Fin pitch mm 18.00 18.00
  Stages Quantity   32 32
  Tube type   ø8 Hi-XA ø8 Hi-XA
  Fin Type   WF fin WF fin
    Treatment   Anti-corrosion treatment (PE) Anti-corrosion treatment (PE)
Fan Type   Propeller fan Propeller fan
  Quantity   1 1
  Air flow rate Heating High m³/min 45.0 47.0
    Cooling High m³/min 525.0 525.0
  Discharge direction   Horizontal Horizontal
Fan motor Quantity   1 1
  Output W 53 53
Compressor Quantity   1 1
  Model   2YC36BXD#C 2YC45NXD#C
  Type   Hermetically sealed swing compressor Hermetically sealed swing compressor
PED Category   Category I Category I
Operation range Heating Min. °CWB -25 -25
    Max. °CWB 25 25
Sound power level Heating Nom. dBA 61 62
Sound pressure level Heating Nom. dBA 48 (1) 49 (1)
Refrigerant Type   R-410A R-410A
  GWP   2,088 2,088
  Charge TCO2Eq 3.0 3.3
  Charge kg 1.5 1.6
  Control   Expansion valve (electronic type) Expansion valve (electronic type)
  Circuits Quantity   1 1
Refrigerant oil Type   FVC50K FVC50K
  Charged volume l 65.0 8.0
Piping connections Liquid Type   Flare connection Flare connection
    OD mm 6.35 6.35
  Gas Type   Flare connection Flare connection
    OD mm 159.00 159.00
  Drain Quantity   2 2
    Type   Hole Hole
    OD mm 1x ø15 + 1x ø20 1x ø15 + 1x ø20
  Piping length OU - IU Min. m 3 3
      Max. m 20 20
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 20.0 20.0
Defrost method Reversed cycle Reversed cycle
Defrost control Sensor for outdoor heat exchanger temperature Sensor for outdoor heat exchanger temperature
Capacity control Method   Inverter controlled Inverter controlled
Power supply Name   V3 V3
  Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 230 230
  Voltage range Min. % -10 -10
    Max. % 10 10
Current Starting current Heating A 15.7 (2) 15.9 (2)
  Maximum running current Heating A 15.7 (3) 15.9 (3)
  Recommended fuses A 16 20
Wiring connections For power supply Quantity   3 3
  For connection with indoor Quantity   4 4
    Remark   Earth wire included Earth wire included
Notes The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  Standard on/off compressor starting current >> max. running current Standard on/off compressor starting current >> max. running current
  Daikin Altherma inverter controlled compressor starting current always <= max. running current Daikin Altherma inverter controlled compressor starting current always <= max. running current
  Inverter controlled compressor starting current always <= max. running current Inverter controlled compressor starting current always <= max. running current
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases