EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP
Cooling capacity Max. kW 5.28 (1) 6.08 (1) 7.18 (1)
  Min. kW 4.09 (1) 4.09 (1) 4.09 (1)
  Nom. kW 5.28 (1) 6.08 (1) 7.18 (1)
Heating capacity Min. kW 4.42 (2), 4.01 (3) 4.42 (2), 4.01 (3) 4.42 (2), 4.01 (3)
  Max. kW 7.19 (2), 6.75 (3) 8.50 (2), 8.05 (3) 9.10 (2), 8.65 (3)
  Nom. kW 6.02 (2), 5.57 (3) 6.72 (2), 6.27 (3) 8.18 (2), 7.67 (3)
Capacity control Method   Inverter controlled Inverter controlled Inverter controlled
Power input Cooling Nom. kW 1.94 (1) 2.40 (1) 3.00 (1)
  Heating Nom. kW 1.65 (2), 2.02 (3) 1.89 (2), 2.29 (3) 2.41 (2), 2.88 (3)
EER 2.72 (1) 2.53 (1) 2.39 (1)
COP 3.65 (2), 2.76 (3) 3.58 (2), 2.74 (3) 3.39 (2), 2.66 (3)
Dimensions Packed unit Depth mm 442 442 442
    Height mm 915 915 915
    Width mm 1,265 1,265 1,265
  Unit Depth mm 360 360 360
    Height mm 805 805 805
    Width mm 1,190 1,190 1,190
Weight Operation weight kg 104 104 104
  Packed unit kg 108 108 108
  Unit kg 100 100 100
Casing Colour   Ivory white Ivory white Ivory white
  Material   Polyester painted galvanised steel plate Polyester painted galvanised steel plate Polyester painted galvanised steel plate
Water heat exchanger Type   Brazed plate Brazed plate Brazed plate
  Filter Diameter perforations mm 1.00 1.00 1.00
    Type   Brass Y-strainer Brass Y-strainer Brass Y-strainer
  Minimum water volume in the system l 10 10 10
  Water flow rate Min. l/min 12 12 12
    Heating Nom. l/min 17.5 19.5 23.5
  Insulation material   Polyethylene foam Polyethylene foam Polyethylene foam
  Model Quantity   1 1 1
    Type   ACH30-48 ACH30-48 ACH30-48
Air heat exchanger Type   Tube type Tube type Tube type
  Fin pitch mm 1,8 1,8 1,8
  Rows Quantity   2 2 2
  Stages Quantity   32 32 32
Pump Standard Nominal ESP unit Cooling kPa 51.8 49.3 45.2
    Heating kPa 48.9 46.4 40.6
  Model   YONOS PARA GT25/7.5 RKC130 YONOS PARA GT25/7.5 RKC130 YONOS PARA GT25/7.5 RKC130
  Power input W 130 130 130
  Quantity   1 1 1
  Type   Water cooled Water cooled Water cooled
Hydraulic components Anti freeze heater (optional) W 75 75 75
  Expansion vessel Pre pressure bar 1 1 1
    Volume l 6 6 6
  Safety valve bar 3 3 3
  Unit water volume l 5.50 (4) 5.50 (4) 5.50 (4)
  Water filter Diameter inch 1" 1" 1"
Fan Quantity   1 1 1
  Type   Propeller fan Propeller fan Propeller fan
  Discharge direction   Horizontal Horizontal Horizontal
Fan motor Output W 53 53 53
Refrigerant oil Type   FVC50K FVC50K FVC50K
  Charged volume l 0.750 0.750 0.750
Compressor Quantity   1 1 1
  Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
  Model   2YC63BXD#C 2YC63BXD#C 2YC63BXD#C
  Output W 1,920 1,920 1,920
  Starting method   Inverter driven Inverter driven Inverter driven
Operation range Air side Cooling Max. °CDB 43 43 43
      Min. °CDB 10 10 10
    Heating Max. °CDB 25 25 25
      Min. °CDB -15 -15 -15
  Water side Cooling Max. °CDB 20 20 20
      Min. °CDB 5.00 5.00 5.00
    Heating Max. °CDB 50 50 50
      Min. °CDB 30 30 30
Sound power level Cooling Nom. dBA 62.0 62.0 63.0
Sound pressure level Cooling Nom. dBA 50 (5) 50 (5) 50 (5)
  Heating Nom. dBA 50 (5) 50 (5) 50 (5)
Refrigerant Type   R-410A R-410A R-410A
  GWP   2,087.5 2,087.5 2,087.5
  Circuits Quantity   1.00 1.00 1.00
  Control   Inverter Inverter Inverter
Charge Per circuit kg 1.70 1.70 1.70
  Per circuit TCO2Eq 3.55 3.55 3.55
Piping connections Water heat exchanger drain   5/16 SAE flare 5/16 SAE flare 5/16 SAE flare
Water circuit Piping connections diameter inch 1" MBSP 1" MBSP 1" MBSP
Safety devices Item 01   Fan motor thermal protection Fan motor thermal protection Fan motor thermal protection
    02   Fuse Fuse Fuse
    03   Safety valve Safety valve Safety valve
    04   Flowswitch Flowswitch Flowswitch
General Supplier/Manufacturer details Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name or trademark   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Air-to-water heat pump   Yes Yes Yes
    Brine-to-water heat pump   No No No
    Heat pump combination heater   No No No
    Low-temperature heat pump   Yes Yes Yes
    Supplementary heater integrated   Yes Yes Yes
    Water-to-water heat pump   No No No
LW(A) Sound power level (according to EN14825) dB(A) 62.0 62.0 63.0
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825 Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,820 2,820 2,820
  Other Capacity control   Inverter Inverter Inverter
    Cdh (Degradation heating)   1.00 1.00 1.00
    Pck (Crankcase heater mode) kW 0.032 0.032 0.032
    Poff (Off mode) kW 0.011 0.011 0.011
    Psb (Standby mode) kW 0.011 0.011 0.011
    Pto (Thermostat off) kW 0.054 0.054 0.054
  Integrated supplementary heater NOx emission mg/kWh 0.00 0.00 0.00
    Psup kW 0.00 0.00 0.00
    Type of energy input   Electrical Electrical Electrical
Space heating Average climate water outlet 35°C General Annual energy consumption kWh 3,710 4,120 4,950
      Ƞs (Seasonal space heating efficiency) % 133 133 134
      Prated at -10°C kW 6.10 6.80 8.20
      Qhe Annual energy consumption (GCV) Gj 13.3 14.8 17.8
      SCOP   3.39 3.40 3.41
      Seasonal space heating eff. class   A+ A+ A+
    A Condition (-7°CDB/-8°CWB) COPd   2.32 2.28 2.21
      Pdh kW 4.50 5.20 6.00
      PERd % 92.8 91.2 88.4
    B Condition (2°CDB/1°CWB) Cdh (Degradation heating)   1.00 1.00 1.00
      COPd   3.36 3.29 3.28
      Pdh kW 3.40 3.60 4.40
      PERd % 134 132 131
    C Condition (7°CDB/6°CWB) Cdh (Degradation heating)   1.00 1.00 1.00
      COPd   4.44 4.58 4.74
      Pdh kW 2.20 2.30 2.90
      PERd % 178 183 190
    D Condition (12°CDB/11°CWB) Cdh (Degradation heating)   1.00 1.00 1.00
      COPd   6.11 6.24 6.55
      Pdh kW 2.60 2.60 2.60
      PERd % 244 250 262
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 2.10 2.10 2.80
    Tbiv (bivalent temperature) COPd   2.47 2.44 2.35
      Pdh kW 4.80 5.50 6.40
      PERd % 98.8 97.6 94.0
      Tbiv °C -5.00 -5.00 -5.00
    Tol (temperature operating limit) COPd   2.10 2.09 2.03
      Pdh kW 4.00 4.70 5.50
      PERd % 84.0 83.6 81.2
      TOL °C -10.0 -10.0 -10.0
      WTOL °C 35.0 35.0 35.0
  Cold climate water outlet 35°C General Annual energy consumption kWh 4,850 5,980 6,850
      Ƞs (Seasonal space heating efficiency) % 113 109 108
      Prated at -22°C kW 5.70 6.80 7.70
      Qhe Annual energy consumption (GCV) Gj 17.5 21.5 24.6
  Warm climate water outlet 35°C General Annual energy consumption kWh 1,770 2,190 2,370
      Ƞs (Seasonal space heating efficiency) % 177 173 173
      Prated at 2°C kW 6.20 7.40 8.00
      Qhe Annual energy consumption (GCV) Gj 6.37 7.89 8.52
Power supply Name   V3 V3 V3
  Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 230 230 230
  Voltage range Min. % -10 -10 -10
    Max. % 10 10 10
Unit Starting current Nom. A 11.0 11.0 11.0
  Running current Max A 19.0 19.0 19.0
  Minimum Ssc value   Equipment complying with EN/IEC 61000-3-12 Equipment complying with EN/IEC 61000-3-12 Equipment complying with EN/IEC 61000-3-12
  Recommended fuses according to IEC standard 269-2   20 20 20
Fans Quantity   1 1 1
  Phase   1~ 1~ 1~
  Voltage V 230 230 230
Pump Standard Phase   1~ 1~ 1~
  Power input kW 0.130 0.130 0.130
  Voltage V 230 230 230
  Maximum running current A 0.580 0.580 0.580
  Speed Min. rpm 1,050 1,050 1,050
    Nom. rpm 2,250 2,250 2,250
    Max. rpm 2,450 2,450 2,450
Evaporator heater tape Supply voltage V 230 230 230
  Capacity W 75 75 75
  Voltage range Min. % -10 -10 -10
    Max. % 10 10 10
  Recommended fuses   25A 25A 25A
Notes Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  Including piping + PHE; excluding expansion vessel Including piping + PHE; excluding expansion vessel Including piping + PHE; excluding expansion vessel
  The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases