Specifications Table for FBQ-C8 / RZQG-L(8)Y1

FBQ71C8VEB / RZQG71L8Y1B FBQ100C8VEB / RZQG100L8Y1B FBQ125C8VEB / RZQG125L8Y1B FBQ140C8VEB / RZQG140L7Y1B
Poff (Off mode) W 0      
Cooling Psb (Standby mode cooling) W 7      
  Cooling-=-Cooling cdc degradation cooling 0.25      
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 6.8      
    Annual energy consumption kWh 390      
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.11      
    D Condition (20°C - 27/19) Pdc kW 4.06      
      power input kW 0.41      
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.1      
    C Condition (25°C - 27/19) power input kW 0.5      
      Pdc kW 3.92      
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.84      
    A Condition (35°C - 27/19) power input kW 1.95      
      Pdc kW 6.8      
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.5      
    B Condition (30°C - 27/19) Pdc kW 5.01      
      power input kW 1.04      
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.85      
  Heating (Average climate) Annual energy consumption kWh 2,095      
    Pdesign kW 6      
    Required back up heating cap at design conditions kW 0.28      
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+      
    TBivalent Pdh (declared heating cap) kW 5.31      
      Power input kW 1.91      
      Tbiv (bivalent temperature) °C -7      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.79      
    C Condition (7°C) Pdh (declared heating cap) kW 2.84      
      Power input kW 0.61      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.72      
    TOL Tol (temperature operating limit) °C -15      
      Pdh (declared heating cap) kW 6.38      
      Power input kW 3.28      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.95      
    A Condition (-7°C) Pdh (declared heating cap) kW 5.31      
      Power input kW 1.91      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.79      
    D Condition (12°C) Pdh (declared heating cap) kW 3.23      
      Power input kW 0.6      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.45      
    B Condition (2°C) Power input kW 0.76      
      Pdh (declared heating cap) kW 3.23      
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.29      
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4
Pck (Crankcase heater mode) W 0      
Nominal efficiency Annual energy consumption kWh 970 (0.000) 1,220 1,575 2,010 (0.000)
  Energy labeling Directive Heating A      
  Nominal efficiency-=-Cop 3.50     3.33
Heating Psb (Standby mode heating) W 7      
  Heating-=-Heating cdh degradation heating 0.25      
Heating capacity Nom. kW 7.5 10.8 13.5 15.5
Pto (Thermostat off) W 7      
Power input Cooling Nom. kW 1.94     4.02
  Heating Nom. kW 2.05     4.30
Cold season included Yes      
Notes EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Nominal efficiency EER     3.89 3.81  
  COP     4.21 3.83  
  Energy labeling Directive Cooling     A A  
    Heating     A A  
Space cooling Energy efficiency class     A+ A+  
  Capacity Pdesign kW   9.5 12  
  SEER     5.8 5.81  
  Annual energy consumption kWh/a   574 723  
Space heating (Average climate) Energy efficiency class     A++ A+  
  Capacity Pdesign kW   11.3 12.71  
  SCOP/A     4.61 4.21  
  Annual energy consumption kWh/a   3,432 4,227