FCAG50AVEB / RZAG35A2V1B FCAG35AVEB / RZAG35A2V1B FCAG60AVEB / RZAG50A2V1B FCAG50AVEB / RZAG50A2V1B FCAG60AVEB / RZAG60A2V1B FCAG71AVEB / RZAG60A2V1B
Indoor unit FCAG50AVEB FCAG35AVEB FCAG60AVEB FCAG50AVEB FCAG60AVEB FCAG71AVEB
Outdoor unit RZAG35A2V1B RZAG35A2V1B RZAG50A2V1B RZAG50A2V1B RZAG60A2V1B RZAG60A2V1B
Cooling capacity Min. kW 1.6 1.6 1.7 1.7 1.7 1.7
  Min. Btu/h 5,500.0 5,500.0 5,800.0 5,800.0 5,800.0 5,800.0
  Min. kcal/h 1,376.0 1,376.0 1,462.0 1,462.0 1,462.0 1,462.0
  Nom. kW 3.5 3.5 5.0 5.0 6.0 6.0
  Nom. Btu/h 11,900.0 11,900.0 17,100.0 17,100.0 20,500.0 20,500.0
  Nom. kcal/h 3,009.0 3,009.0 4,299.0 4,299.0 5,159.0 5,159.0
  Max. kW 4.5 4.5 6.0 6.0 6.5 6.5
  Max. Btu/h 15,400.0 15,400.0 20,500.0 20,500.0 22,200.0 22,200.0
  Max. kcal/h 3,869.0 3,869.0 5,159.0 5,159.0 5,589.0 5,589.0
Heating capacity Min. kW 1.40 1.40 1.50 1.50 1.60 1.60
  Min. Btu/h 4,800.0 4,800.0 5,100.0 5,100.0 5,500.0 5,500.0
  Min. kcal/h 1,200.0 1,200.0 1,300.0 1,290.0 1,380.0 1,400.0
  Nom. kW 4.00 4.00 5.80 5.80 7.00 7.00
  Nom. Btu/h 13,600.0 13,700.0 19,800.0 19,800.0 23,900.0 23,900.0
  Nom. kcal/h 3,439.0 3,439.0 4,987.0 4,987.0 6,019.0 6,019.0
  Max. kW 5.00 5.00 6.00 6.00 7.50 7.50
  Max. Btu/h 17,100.0 17,000.0 20,500.0 20,500.0 25,600.0 25,600.0
  Max. kcal/h 4,299.0 4,299.0 5,159.0 5,159.0 6,449.0 6,449.0
Power input Cooling Nom. kW 0.77 0.80 1.26 1.28 1.76 1.58
  Heating Nom. kW 0.91 0.93 1.55 1.56 2.06 1.98
Nominal efficiency EER   4.57 4.40 3.98 3.90 3.40 3.79
  COP   4.41 4.30 3.75 3.71 3.40 3.53
  Annual energy consumption kWh 383 398 628 641 882 792
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A C B
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 3.50 3.50 5.00 5.00 6.00 6.00
  SEER   7.40 7.30 6.93 6.80 6.60 6.82
  Annual energy consumption kWh/a 166 168 252 257 318 308
  A Condition (35°C - 27/19) Pdc kW 3.50 3.50 5.00 5.00 6.00 6.00
    EERd   4.57 4.40 3.98 3.90 3.40 3.79
    Power input kW 0.77 0.80 1.26 1.28 1.76 1.58
  B Condition (30°C - 27/19) Pdc kW 2.58 2.58 3.68 3.68 4.42 4.42
    EERd   6.92 7.04 5.95 5.82 5.74 5.92
    Power input kW 0.37 0.37 0.62 0.63 0.77 0.75
  C Condition (25°C - 27/19) Pdc kW 1.87 1.50 2.37 2.37 2.84 2.84
    EERd   10.74 9.98 8.54 8.41 7.65 7.89
    Power input kW 0.17 0.15 0.28 0.28 0.37 0.36
  D Condition (20°C - 27/19) Pdc kW 1.85 1.59 1.88 1.85 1.88 1.92
    EERd   13.42 13.20 13.30 12.89 12.82 12.98
    Power input kW 0.14 0.12 0.14 0.14 0.15 0.15
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+ A+ A+
  Capacity Pdesign kW 3.30 3.30 4.30 4.30 4.60 4.60
  SCOP/A   4.41 4.30 4.35 4.30 4.25 4.39
  SCOPnet/A   4.45 4.34 4.39 4.34 4.29 4.43
  Pdh Heating capacity at -10° kW 2.91 2.91 3.73 3.68 3.96 4.00
  Annual energy consumption kWh/a 1,048 1,074 1,384 1,398 1,515 1,467
  Required back up heating cap at design conditions kW 0.39 0.39 0.57 0.62 0.64 0.60
  TOL Tol (temperature operating limit) °C -20 -20 -20 -20 -20 -20
    Pdh (declared heating cap) kW 2.90 2.87 3.47 3.30 3.59 3.77
    COPd (declared COP)   2.28 2.24 2.16 2.15 2.11 2.19
    Power input kW 1.27 1.28 1.61 1.53 1.70 1.72
  TBivalent Tbiv (bivalent temperature) °C -7.0 -7 -7.0 -7 -7 -7.0
    Pdh (declared heating cap) kW 2.92 2.92 3.81 3.80 4.07 4.07
    COPd (declared COP)   2.79 2.71 2.68 2.65 2.59 2.69
    Power input kW 1.05 1.08 1.42 1.43 1.57 1.51
  A Condition (-7°C) Pdh (declared heating cap) kW 2.92 2.92 3.81 3.80 4.07 4.07
    COPd (declared COP)   2.79 2.71 2.68 2.65 2.59 2.69
    Power input kW 1.05 1.08 1.42 1.43 1.57 1.51
  B Condition (2°C) Pdh (declared heating cap) kW 1.78 1.78 2.32 2.32 2.48 2.48
    COPd (declared COP)   4.27 4.14 4.13 4.08 4.02 4.17
    Power input kW 0.42 0.43 0.56 0.57 0.62 0.59
  C Condition (7°C) Pdh (declared heating cap) kW 1.51 1.42 1.52 1.51 1.59 1.59
    COPd (declared COP)   6.33 6.18 6.19 6.16 6.12 6.25
    Power input kW 0.24 0.23 0.25 0.25 0.26 0.25
  D Condition (12°C) Pdh (declared heating cap) kW 1.60 1.57 1.61 1.60 1.61 1.63
    COPd (declared COP)   8.02 7.83 7.97 7.88 7.88 8.05
    Power input kW 0.20 0.20 0.20 0.20 0.20 0.20
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000 0.000 0.000 0.000 0.000
    Heating PCK kW 0.000 0.000 0.000 0.000 0.000 0.000
  Off mode Cooling POFF kW 0.012 0.012 0.012 0.012 0.012 0.012
    Heating POFF kW 0.012 0.012 0.012 0.012 0.012 0.012
  Standby mode Cooling PSB kW 0.012 0.012 0.012 0.012 0.012 0.012
    Heating PSB kW 0.012 0.012 0.012 0.012 0.012 0.012
  Thermostat-off mode Cooling PTO kW 0.004 0.004 0.004 0.004 0.004 0.004
    Heating PTO kW 0.023 0.023 0.023 0.023 0.023 0.023
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No
Warm season included No No No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 62 62 63 63 64 64
  Sound power level indoor Cooling Nom. dBA 49 49 51 49 51 51
  Piping length Cooling Measuring condition m 5.0 5.0 5.0 5.0 5.0 5.0