Specifications Table for FDXM-F3 / RXM-M9

FDXM25F3V1B / RXM25M3V1B9 FDXM35F3V1B / RXM35M3V1B9 FDXM50F3V1B / RXM50M3V1B9 FDXM60F3V1B / RXM60M3V1B9
Cooling capacity Min. kW 1.30 1.40 1.70 1.70
  Nom. kW 2.40 3.40 5.00 6.00
  Max. kW 3.00 3.80 5.30 6.50
Heating capacity Min. kW 1.30 1.40 1.70 1.70
  Nom. kW 3.20 4.00 5.80 7.00
  Max. kW 4.50 5.00 6.00 7.10
Nominal efficiency EER   3.77 2.98 3.06 2.93
  COP   4.00 3.48 3.10 3.21
  Annual energy consumption kWh 318 570 816 1,024
  Energy labeling Directive Cooling   A C B C
    Heating   A B D C
Space cooling Energy efficiency class   A+ A A+ A
  Capacity Pdesign kW 2.40 3.40 5.00 6.00
  SEER   5.68 5.26 5.77 5.56
  Annual energy consumption kWh/a 148 226 303 315
Space heating (Average climate) Energy efficiency class   A+ A A A
  Capacity Pdesign kW 2.60 2.90 4.00 4.60
  SCOP/A   4.24 3.88 3.93 3.80
  Annual energy consumption kWh/a 858 1,046 1,424 1,693
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.