FDXM25F3V1B / RXM25M3V1B9 FDXM35F3V1B / RXM35M3V1B9 FDXM50F3V1B / RXM50M3V1B9 FDXM60F3V1B / RXM60M3V1B9
Indoor unit FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B
Outdoor unit RXM25M3V1B9 RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9
Cooling capacity Min. kW 1.30 1.40 1.70 1.70
  Min. Btu/h 4,435 4,776 5,800 5,801
  Min. kcal/h 1,117 1,203 1,461 1,462
  Nom. kW 2.40 3.40 5.00 6.00
  Nom. Btu/h 8,189 11,601 17,061 20,472.9
  Nom. kcal/h 2,064 2,923 4,299 5,159.1
  Max. kW 3.00 3.80 5.30 6.50
  Max. Btu/h 10,236 12,966 18,084 22,179
  Max. kcal/h 2,579 3,267 4,557 5,589
Heating capacity Min. kW 1.30 1.40 1.70 1.70
  Min. Btu/h 4,435 4,776 5,800 5,801
  Min. kcal/h 1,117 1,203 1,461 1,462
  Nom. kW 3.20 4.00 5.80 7.00
  Nom. Btu/h 10,919 13,649 19,790 23,885.0
  Nom. kcal/h 2,752 3,439 4,987 6,018.9
  Max. kW 4.50 5.00 6.00 7.10
  Max. Btu/h 15,354 17,060 20,472 24,226
  Max. kcal/h 3,869 4,299 5,159 6,105
Power input Cooling Nom. kW 0.64 1.14 1.63 2.05
  Heating Nom. kW 0.80 1.15 1.87 2.18
Nominal efficiency EER   3.77 2.98 3.06 2.93
  COP   4.00 3.48 3.10 3.21
  Annual energy consumption kWh 318 570 816 1,024
  Energy labeling Directive Cooling   A C B C
    Heating   A B D C
Space cooling Energy efficiency class   A+ A A+ A
  Capacity Pdesign kW 2.40 3.40 5.00 6.00
  SEER   5.68 5.26 5.77 5.56
  Annual energy consumption kWh/a 148 226 303 315
  A Condition (35°C - 27/19) Pdc kW 2.40 3.40 5.00 6.00
    EERd   3.77 2.98 3.06 2.93
    Power input kW 0.64 1.14 1.63 2.05
  B Condition (30°C - 27/19) Pdc kW 1.76 2.50 3.67 4.43
    EERd   5.38 4.08 4.96 4.39
    Power input kW 0.33 0.61 0.74 1.01
  C Condition (25°C - 27/19) Pdc kW 1.27 1.61 2.37 2.85
    EERd   8.92 8.05 8.21 7.94
    Power input kW 0.14 0.20 0.29 0.36
  D Condition (20°C - 27/19) Pdc kW 1.31 1.46 2.26 2.26
    EERd   10.90 9.65 9.47 8.87
    Power input kW 0.12 0.15 0.24 0.26
Space heating (Average climate) Energy efficiency class   A+ A A A
  Capacity Pdesign kW 2.60 2.90 4.00 4.60
  SCOP/A   4.24 3.88 3.93 3.80
  SCOPnet/A   4.27 3.90 3.95 3.82
  Pdh Heating capacity at -10° kW 2.16 2.42 3.55 3.94
  Annual energy consumption kWh/a 858 1,046 1,424 1,693
  Required back up heating cap at design conditions kW 0.44 0.48 0.45 0.66
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.93 2.15 3.59 3.72
    COPd (declared COP)   2.20 2.01 1.89 1.91
    Power input kW 0.88 1.07 1.90 1.94
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7
    Pdh (declared heating cap) kW 2.30 2.57 3.54 4.07
    COPd (declared COP)   2.81 2.60 2.87 2.58
    Power input kW 0.82 0.99 1.23 1.58
  A Condition (-7°C) Pdh (declared heating cap) kW 2.30 2.57 3.54 4.07
    COPd (declared COP)   2.81 2.60 2.87 2.58
    Power input kW 0.82 0.99 1.23 1.58
  B Condition (2°C) Pdh (declared heating cap) kW 1.40 1.57 2.13 2.48
    COPd (declared COP)   4.21 3.84 4.10 3.92
    Power input kW 0.33 0.41 0.52 0.63
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 1.02 1.62 1.62
    COPd (declared COP)   5.54 4.94 4.56 4.52
    Power input kW 0.18 0.21 0.36 0.36
  D Condition (12°C) Pdh (declared heating cap) kW 1.17 1.19 1.92 1.92
    COPd (declared COP)   6.84 6.08 5.49 5.46
    Power input kW 0.17 0.20 0.35 0.35
Space heating (Warm climate) Energy efficiency class   A+++ A++ A+ A+
  Capacity Pdesignh kW 1.40 1.57 2.13 2.48
  SCOP   5.38 4.88 4.40 4.47
  SCOPnet   5.46 4.94 4.44 4.51
  Annual energy consumption kWh/a 365 450 679 777
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.93 2.15 3.59 3.72
    COPd (declared COP)   2.20 2.01 1.89 1.91
    Power input kW 0.88 1.07 1.90 1.94
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2
    Pdh (declared heating cap) kW 1.40 1.57 2.13 2.48
    COPd (declared COP)   4.21 3.84 4.10 3.92
    Power input kW 0.33 0.41 0.52 0.63
  B Condition (2°C) Pdh (declared heating cap) kW 1.40 1.57 2.13 2.48
    COPd (declared COP)   4.21 3.84 4.10 3.92
    Power input kW 0.33 0.41 0.52 0.63
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 1.02 1.62 1.62
    COPd (declared COP)   5.54 4.94 4.56 4.52
    Power input kW 0.18 0.21 0.36 0.36
  D Condition (12°C) Pdh (declared heating cap) kW 1.17 1.19 1.92 1.92
    COPd (declared COP)   6.84 6.08 5.49 5.46
    Power input kW 0.17 0.20 0.35 0.35
Power consumption in other than active mode Off mode Cooling POFF kW 14.0 14.0    
    Heating POFF kW 14.0 14.0    
  Standby mode Cooling PSB kW 14.0 14.0 15.0 15
    Heating PSB kW 14.0 14.0 15.0 15
  Thermostat-off mode Cooling PTO kW 7.0 7.0 9.0 9
    Heating PTO kW 7.0 7.0 9.0 9
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes
Cold season included No No No No
Warm season included Yes Yes Yes Yes
Ecolabel logo No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 59 61 62 63
  Sound power level indoor Cooling Nom. dBA 53 53 55 56
  Piping length Cooling Measuring condition m 5.0 5.0 5.0 5
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.