FDXS50F2VEB9 / RXS50L2V1B
Poff (Off mode) W 15.0
Cooling Psb (Standby mode cooling) W 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 5.00
    Annual energy consumption kWh 306
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.72
    D Condition (20°C - 27/19) Pdc kW 2.26
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.38
    C Condition (25°C - 27/19) Pdc kW 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.41
    A Condition (35°C - 27/19) Pdc kW 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.41
    B Condition (30°C - 27/19) Pdc kW 3.67
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.91
  Heating (Average climate) Annual energy consumption kWh 1,425
    Pdesign kW 4.00
    Required back up heating cap at design conditions kW 0.45
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (declared heating cap) kW 3.54
      Tbiv (bivalent temperature) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.43
    C Condition (7°C) Pdh (declared heating cap) kW 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.92
    TOL Tol (temperature operating limit) °C -15
      Pdh (declared heating cap) kW 3.59
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.88
    A Condition (-7°C) Pdh (declared heating cap) kW 3.54
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.43
    D Condition (12°C) Pdh (declared heating cap) kW 1.92
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.15
    B Condition (2°C) Pdh (declared heating cap) kW 2.15
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.11
Cooling capacity Nom. Btu/h 17,100
  Min. kW 1.7
  Nom. kcal/h 4,300
  Max. kW 5.3
  Min. kcal/h 1,460
  Min. Btu/h 5,800
  Nom. kW 5.0
  Max. Btu/h 18,100
  Max. kcal/h 4,560
Pck (Crankcase heater mode) W 0.0
Nominal efficiency Annual energy consumption kWh 825 (0.000)
  Energy labeling Directive Heating B
  Nominal efficiency-=-Cop 3.03
Heating Heating-=-Heating cdh degradation heating 0.25
Piping connections Liquid OD mm 6.35
  Gas OD mm 12.7
  Drain OD mm VP20 (External dia.26, Internal dia. 20)
  Heat insulation Both liquid and gas pipes
Heating capacity Min. Btu/h 5,800
  Nom. Btu/h 19,800
  Max. kcal/h 5,160
  Max. Btu/h 20,500
  Nom. kW 5.8
  Min. kW 1.7
  Nom. kcal/h 4,990
  Min. kcal/h 1,460
  Max. kW 6.0
Pto (Thermostat off) W 9.0
Power input Cooling Nom. kW 1.650
  Heating Nom. kW 1.870
Cold season included Yes
Current Nominal running current (RLA) - 50Hz Heating A 8.3 (2)
    Cooling A 7.1 (2)
Notes EER/COP according to Eurovent 2012, for use outside EU only
  230V