FHA35AVEB / RXM35M3V1B9 FHA50AVEB / RXM50M3V1B9 FHA60AVEB / RXM60M3V1B9
Indoor unit FHA35AVEB FHA50AVEB FHA60AVEB
Outdoor unit RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9
Cooling capacity Nom. kW 3.40 5.00 5.70
  Nom. Btu/h 11,601 17,061 19,449
  Nom. kcal/h 2,923 4,299 4,901
Heating capacity Nom. kW 4.00 6.00 7.20
  Nom. Btu/h 13,649 20,473 24,567
  Nom. kcal/h 3,439 5,159 6,191
Power input Cooling Nom. kW 0.91 1.56 1.73
  Heating Nom. kW 0.98 1.79 2.17
Nominal efficiency EER   3.73 3.21 3.29
  COP   4.08 3.35 3.32
  Annual energy consumption kWh 456 (0.000) 780 (0.000) 867 (0.000)
  Energy labeling Directive Cooling   A B A
    Heating   A C C
Space cooling Energy efficiency class   A++ A+ A+
  Capacity Pdesign kW 3.40 5.00 5.70
  SEER   6.24 5.92 6.08
  Annual energy consumption kWh/a 191 295 328
  A Condition (35°C - 27/19) Pdc kW 3.40 5.00 5.70
    EERd   3.73 3.21 3.29
    Power input kW 0.91 1.56 1.73
  B Condition (30°C - 27/19) Pdc kW 2.51 3.69 4.43
    EERd   5.28 5.04 4.88
    Power input kW 0.48 0.73 0.91
  C Condition (25°C - 27/19) Pdc kW 1.68 2.37 2.85
    EERd   9.59 8.25 8.34
    Power input kW 0.18 0.29 0.34
  D Condition (20°C - 27/19) Pdc kW 1.64 2.31 2.26
    EERd   11.71 10.39 10.97
    Power input kW 0.14 0.22 0.21
Space heating (Average climate) Energy efficiency class   A+ A A
  Capacity Pdesign kW 3.10 4.35 4.71
  SCOP/A   4.43 3.86 3.87
  SCOPnet/A   4.47 3.87 3.89
  Pdh Heating capacity at -10° kW 2.63 3.85 4.08
  Annual energy consumption kWh/a 979 1,578 1,704
  Required back up heating cap at design conditions kW 0.47 0.50 0.63
  TOL Tol (temperature operating limit) °C -15 -15 -15
    Pdh (declared heating cap) kW 2.47 3.86 3.92
    COPd (declared COP)   2.23 1.97 1.97
    Power input kW 1.11 1.96 1.99
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7
    Pdh (declared heating cap) kW 2.74 3.85 4.12
    COPd (declared COP)   2.94 2.61 2.64
    Power input kW 0.93 1.48 1.56
  A Condition (-7°C) Pdh (declared heating cap) kW 2.74 3.85 4.12
    COPd (declared COP)   2.94 2.61 2.64
    Power input kW 0.93 1.48 1.56
  B Condition (2°C) Pdh (declared heating cap) kW 1.67 2.33 2.54
    COPd (declared COP)   4.32 3.95 3.96
    Power input kW 0.39 0.59 0.64
  C Condition (7°C) Pdh (declared heating cap) kW 1.14 1.54 1.63
    COPd (declared COP)   5.83 4.62 4.60
    Power input kW 0.20 0.33 0.36
  D Condition (12°C) Pdh (declared heating cap) kW 1.34 1.80 1.74
    COPd (declared COP)   7.24 5.65 5.65
    Power input kW 0.19 0.32 0.31
Space heating (Warm climate) Energy efficiency class   A+++ A+ A++
  Capacity Pdesignh kW 1.67 2.33 2.54
  SCOP   5.72 4.59 4.61
  SCOPnet   5.82 4.63 4.66
  Annual energy consumption kWh/a 409 711 771
  Required back up heating cap at design conditions kW 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15
    Pdh (declared heating cap) kW 2.47 3.86 3.92
    COPd (declared COP)   2.23 1.97 1.97
    Power input kW 1.11 1.96 1.99
  TBivalent Tbiv (bivalent temperature) °C 2 2 2
    Pdh (declared heating cap) kW 1.67 2.33 2.54
    COPd (declared COP)   4.32 3.95 3.96
    Power input kW 0.39 0.59 0.64
  B Condition (2°C) Pdh (declared heating cap) kW 1.67 2.33 2.54
    COPd (declared COP)   4.32 3.95 3.96
    Power input kW 0.39 0.59 0.64
  C Condition (7°C) Pdh (declared heating cap) kW 1.14 1.54 1.63
    COPd (declared COP)   5.83 4.62 4.60
    Power input kW 0.20 0.33 0.35
  D Condition (12°C) Pdh (declared heating cap) kW 1.34 1.80 1.74
    COPd (declared COP)   7.24 5.65 5.65
    Power input kW 0.19 0.32 0.31
Power consumption in other than active mode Off mode Cooling POFF kW 14.0    
    Heating POFF kW 14.0    
  Standby mode Cooling PSB kW 14.0    
    Heating PSB kW 14.0    
  Thermostat-off mode Cooling PTO kW 10.0    
    Heating PTO kW 10.0    
Pto (Thermostat off) W   10.0 10.00
Cooling Cdc (Degradation cooling)   0.25    
Heating Cdh (Degradation heating)   0.25    
Cooling function included Yes Yes Yes
Heating function included Yes Yes Yes
Average climate included Yes Yes Yes
Cold season included No No No
Warm season included Yes Yes Yes
Ecolabel logo No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 62 63
  Sound power level indoor Cooling Nom. dBA 53 54 54
  Piping length Cooling Measuring condition m 5.0 5.0 5
Notes (1) - See separate drawing for electrical data See separate drawing for operation range See separate drawing for operation range
  (2) - See separate drawing for operation range See separate drawing for electrical data See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Power consumption in other than active mode Standby mode Cooling PSB W   15.0 15.00
    Heating PSB W   15.0 15.00
Cooling Cdc (Degradation cooling)     0.25 0.25
Heating Cdh (Degradation heating)     0.25 0.25