FLXS25BAVMB / RXS25K3V1B FLXS25BAVMB / RXS25K2V1B FLXS35BAVMB / RXS35K2V1B FLXS50BAVMB / RXS50K2V1B
Poff (Off mode) W 20.0   20.0 20.0
Cooling Psb (Standby mode cooling) W 20.0   20.0 20.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.50   3.50 4.90
    Annual energy consumption kWh 196   273 337
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.46   4.49 5.09
    D Condition (20°C - 27/19) Pdc kW 1.77   1.70 2.11
      power input kW       0.21
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.34   8.85 10.04
    C Condition (25°C - 27/19) power input kW       0.32
      Pdc kW 1.67   1.66 2.32
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.50   6.83 7.19
    A Condition (35°C - 27/19) power input kW       1.59
      Pdc kW 2.50   3.50 4.90
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.70   2.85 3.08
    B Condition (30°C - 27/19) Pdc kW 1.84   2.58 3.61
      power input kW       0.76
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.90   4.54 4.78
  Heating (Average climate) Annual energy consumption kWh 1,080   1,186 1,708
    Pdesign kW 2.80   2.90 4.50
    Required back up heating cap at design conditions kW 0.51   0.55 0.87
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A   A A
    TBivalent Pdh (declared heating cap) kW 2.48   2.57 3.98
      Power input kW       1.83
      Tbiv (bivalent temperature) °C -7   -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.16   2.04 2.17
    C Condition (7°C) Pdh (declared heating cap) kW 1.44   1.39 1.59
      Power input kW       0.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.84   4.53 4.65
    TOL Tol (temperature operating limit) °C -15   -15 -15
      Pdh (declared heating cap) kW 1.98   1.99 3.06
      Power input kW       1.71
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.83   1.70 1.79
    A Condition (-7°C) Pdh (declared heating cap) kW 2.48   2.57 3.98
      Power input kW       1.83
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.16   2.04 2.17
    D Condition (12°C) Pdh (declared heating cap) kW 1.69   1.63 1.86
      Power input kW       0.32
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.75   5.44 5.82
    B Condition (2°C) Power input kW       0.62
      Pdh (declared heating cap) kW 1.51   1.56 2.42
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.93   3.68 3.90
Cooling capacity Nom. Btu/h 8,500 (2) 8,500 (3) 11,900 (2) 16,730 (2)
  Min. kW 1.2 1.2 1.2 0.9
  Nom. kcal/h 2,150 (2) 2,150 (3) 3,010 (2) 4,210 (2)
  Max. kW 3.0 3.0 3.8 5.3
  Min. kcal/h 1,030 1,030 1,030 770
  Min. Btu/h 4,100 4,100 4,100 3,070
  Nom. kW 2.5 (2) 2.5 (3) 3.5 (2) 4.9 (2)
  Max. Btu/h 10,200 10,200 13,000 18,090
  Max. kcal/h 2,580 2,580 3,270 4,560
Pck (Crankcase heater mode) W 0.0   0.0 0.0
Nominal efficiency Annual energy consumption kWh 325 (0.000) 325 (0.000) 565 (0.000) 860 (0.000)
  Energy labeling Directive Heating A A B C
  Nominal efficiency-=-Cop 3.85 3.85 3.10 2.85
Heating Heating-=-Heating cdh degradation heating 0.25   0.25 0.25
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 12.7
  Drain OD mm 18.0 18 18.0 18.0
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Heating capacity Min. Btu/h 4,100 4,100 4,100 3,070
  Nom. Btu/h 11,600 (3) 11,600 (4) 13,600 (3) 20,830 (3)
  Max. kcal/h 3,870 3,870 4,300 6,450
  Max. Btu/h 15,400 15,400 17,100 25,610
  Nom. kW 3.4 (3) 3.4 (4) 4.0 (3) 6.1 (3)
  Min. kW 1.2 1.2 1.4 0.9
  Nom. kcal/h 2,920 (3) 2,920 (4) 3,440 (3) 5,250 (3)
  Min. kcal/h 1,030 1,030 1,030 770
  Max. kW 4.5 4.5 5.0 7.5
Pto (Thermostat off) W 80.0   80.0 80.0
Power input Cooling Min. kW 0.300 0.300 0.300 0.450
    Nom. kW 0.650 0.650 1.130 1.720
    Max. kW 0.860 0.860 1.260 1.950
  Heating Max. kW 1.490 1.490 1.850 3.540
    Min. kW 0.290 0.290 0.290 0.310
    Nom. kW 0.980 0.980 1.230 1.820
Cold season included Yes   Yes Yes
Current Nominal running current (RLA) - 50Hz Heating A 4.7 (4), 4.5 (5), 4.3 (6) 4.7 (5), 4.5 (6), 4.3 (7) 5.8 (4), 5.5 (5), 5.3 (6) 8.4 (4), 8.0 (5), 7.7 (6)
    Cooling A 3.7 (4), 3.6 (5), 3.4 (6) 3.7 (5), 3.6 (6), 3.4 (7) 5.3 (4), 5.1 (5), 4.9 (6) 8.0 (4), 7.6 (5), 7.3 (6)
Notes EER/COP according to Eurovent 2012, for use outside EU only Energy label: scale from A (most efficient) to G (less efficient) EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  220V Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m 220V 220V
  230V 220V 230V 230V
  240V 230V 240V 240V
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 240V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
    Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load