FTXJ20MV1BS / RXJ20M2V1B FTXJ20MV1BS / RXJ20M3V1B FTXJ25MV1BS / RXJ25M3V1B FTXJ25MV1BS / RXJ25M2V1B FTXJ35MV1BS / RXJ35M2V1B FTXJ35MV1BS / RXJ35M3V1B FTXJ50MV1BS / RXJ50MV1B
Cooling capacity Min. kW   1.30 0.90     0.90  
  Min. Btu/h   4,400 3,100     3,100  
  Min. kcal/h   1,120 770     770  
  Nom. kW 2.3 2.30 2.40 2.4 3.5 3.50 4.80
  Nom. Btu/h   7,848 8,189     11,942  
  Nom. kcal/h   1,978 2,064     3,009  
  Max. kW   2.80 3.30     4.10  
  Max. Btu/h   9,500 11,300     14,000  
  Max. kcal/h   2,410 2,840     3,530  
Heating capacity Min. kW   1.30 0.90     0.90  
  Min. Btu/h   4,400 3,100     3,100  
  Min. kcal/h   1,120 770     770  
  Nom. kW 2.5 2.50 3.20 3.2 4 4.00 5.80
  Nom. Btu/h   8,530 10,919     13,649  
  Nom. kcal/h   2,150 2,752     3,439  
  Max. kW   4.30 4.70     5.10  
  Max. Btu/h   14,600 16,000     17,400  
  Max. kcal/h   3,700 4,040     4,390  
Power input Cooling Nom. kW 0.50 0.50 0.51 0.51 0.86 0.86 1.43
  Heating Nom. kW 0.50 0.50 0.70 0.70 0.99 0.99 1.59
Nominal efficiency EER   4.64 4.64 4.73 4.73 4.09 4.09 3.35
  COP   5.00 5.00 4.57 4.57 4.04 4.04 3.65
  Annual energy consumption kWh 248 248 254 254 428 428 716
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A A A A A A
Space cooling Capacity Pdesign kW 2.30 2.30 2.40 2.40 3.50 3.50 4.80
  Energy efficiency class   A+++ A+++ A+++ A+++ A++ A++ A++
  SEER   8.73 8.73 8.64 8.64 7.19 7.19 7.02
  Annual energy consumption kWh/a 92 92 97 97 170 170 239
  A Condition (35°C - 27/19) Pdc kW 2.30 2.30 2.40 2.40 3.50 3.50 4.80
    EERd   4.64 4.64 4.73 4.73 4.09 4.09 3.35
    Power input kW 0.50 0.50 0.51 0.51 0.86 0.86 1.43
  B Condition (30°C - 27/19) Pdc kW 1.62 1.69 1.77 1.70 2.53 2.58 3.47
    EERd   7.67 6.83 6.59 7.33 5.44 5.44 5.24
    Power input kW 0.21 0.25 0.27 0.23 0.47 0.47 0.66
  C Condition (25°C - 27/19) Pdc kW 1.27 1.09 1.14 1.27 1.66 1.66 2.36
    EERd   10.69 10.96 10.90 10.55 7.88 7.88 8.64
    Power input kW 0.12 0.10 0.10 0.12 0.21 0.21 0.27
  D Condition (20°C - 27/19) Pdc kW 1.36 1.12 1.12 1.37 1.46 1.46 2.17
    EERd   14.25 14.56 14.28 14.16 13.76 13.76 12.00
    Power input kW 0.10 0.08 0.08 0.10 0.11 0.11 0.18
Space heating (Average climate) Capacity Pdesign kW 2.10 2.10 2.70 2.70 3.00 3.00 4.60
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A+
  SCOP/A   4.61 4.60 4.60 4.60 4.60 4.60 4.28
  SCOPnet/A   4.65 4.65 4.65 4.66 4.64 4.64 4.30
  Pdh Heating capacity at -10° kW 1.80 1.80 2.18 2.18 2.61 2.61 4.16
  Annual energy consumption kWh/a 638 639 821 822 913 913 1,505
  Required back up heating cap at design conditions kW 0.30 0.30 0.52 0.52 0.39 0.39 0.44
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.68 1.68 1.95 1.95 2.56 2.56 4.12
    COPd (declared COP)   2.69 2.69 2.47 2.47 2.41 2.41 2.16
    Power input kW 0.62 0.62 0.79 0.79 1.06 1.06 1.91
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 1.87 1.86 2.39 2.31 2.64 2.64 4.19
    COPd (declared COP)   3.40 3.46 3.17 3.10 3.10 3.10 2.47
    Power input kW 0.55 0.54 0.75 0.75 0.85 0.85 1.70
  A Condition (-7°C) Pdh (declared heating cap) kW 1.87 1.86 2.39 2.31 2.64 2.64 4.19
    COPd (declared COP)   3.40 3.46 3.17 3.10 3.10 3.10 2.47
    Power input kW 0.55 0.54 0.75 0.75 0.85 0.85 1.70
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.13 1.45 1.40 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.78 4.77 4.87 4.80 4.80 4.41
    Power input kW 0.22 0.24 0.30 0.29 0.32 0.32 0.56
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 0.73 0.93 1.00 1.07 1.07 1.63
    COPd (declared COP)   5.37 5.03 5.38 5.37 5.40 5.40 5.24
    Power input kW 0.19 0.15 0.17 0.19 0.20 0.20 0.31
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.87 0.87 0.96 0.99 0.99 1.87
    COPd (declared COP)   6.36 6.71 6.55 6.36 6.42 6.42 7.95
    Power input kW 0.15 0.13 0.13 0.15 0.15 0.15 0.24
Space heating (Warm climate) Capacity Pdesignh kW 1.07 1.07 1.40 1.40 1.53 1.53 2.49
  Energy efficiency class   A++ A+++ A+++ A+++ A+++ A+++ A+++
  SCOP   5.00 5.18 5.38 5.21 5.32 5.32 5.77
  SCOPnet   5.11 5.31 5.48 5.30 5.41 5.41 5.86
  Annual energy consumption kWh/a 300 289 365 376 403 403 604
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.68 1.68 1.95 1.95 2.56 2.56 4.12
    COPd (declared COP)   2.69 2.69 2.47 2.47 2.41 2.41 2.16
    Power input kW 0.62 0.62 0.79 0.79 1.06 1.06 1.91
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2 2 2 2
    Pdh (declared heating cap) kW 1.07 1.07 1.40 1.40 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.89 4.87 4.87 4.80 4.80 4.41
    Power input kW 0.22 0.22 0.29 0.29 0.32 0.32 0.56
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.13 1.45 1.40 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.78 4.77 4.87 4.80 4.80 4.41
    Power input kW 0.22 0.24 0.30 0.29 0.32 0.32 0.56
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 0.73 0.93 1.00 1.07 1.07 1.63
    COPd (declared COP)   5.37 5.03 5.38 5.37 5.40 5.40 5.24
    Power input kW 0.19 0.15 0.17 0.19 0.20 0.20 0.31
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.87 0.87 0.96 0.99 0.99 1.9
    COPd (declared COP)   6.36 6.71 6.55 6.36 6.42 6.42 7.95
    Power input kW 0.15 0.13 0.13 0.15 0.15 0.15 0.24
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0 0.0 0.0 0.0 0.0 0.0
  Off mode POFF W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Standby mode Cooling PSB W 1.0 1.00 1.00 1.0 1.0 1.00 1.0
    Heating PSB W   1.0 1.0     1.0  
  Thermostat-off mode PTO Cooling W   9 9     9  
      Heating W   9.0 9.0     9.0  
Pto (Thermostat off) W 9.0     9.0 9.0   9.0
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No No
Warm season included No Yes Yes No No Yes No
Ecolabel logo   No No     No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61 61 61 63 63 63
  Sound power level indoor Cooling Nom. dBA 54 54 54 54 59 59 60
Notes (0) - EER/COP according to Eurovent 2012, for use outside EU only     (0) - EER/COP according to Eurovent 2012, for use outside EU only (0) - EER/COP according to Eurovent 2012, for use outside EU only   (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Notes_Description   1 1     1