FTXJ20MV1BS / RXJ20M2V1B FTXJ25MV1BS / RXJ25M2V1B FTXJ35MV1BS / RXJ35M2V1B FTXJ50MV1BS / RXJ50MV1B
Cooling capacity Nom. kW 2.3 2.4 3.5 4.80
Heating capacity Nom. kW 2.5 3.2 4 5.80
Power input Cooling Nom. kW 0.50 0.51 0.86 1.43
  Heating Nom. kW 0.50 0.70 0.99 1.59
Nominal efficiency EER   4.64 4.73 4.09  
  COP   5.00 4.57 4.04  
  Annual energy consumption kWh 248 (0.000) 254 (0.000) 428 (0.000) 716 (0.000)
  Energy labeling Directive Cooling   A A A  
    Heating   A A A  
Space cooling Capacity Pdesign kW 2.30 2.40 3.50  
  Energy efficiency class   A+++ A+++ A++  
  SEER   8.73 8.64 7.19  
  Annual energy consumption kWh/a 92 97 170  
  A Condition (35°C - 27/19) Pdc kW 2.30 2.40 3.50  
    EERd   4.64 4.73 4.09  
    Power input kW 0.50 0.51 0.86  
  B Condition (30°C - 27/19) Pdc kW 1.62 1.70 2.53  
    EERd   7.67 7.33 5.44  
    Power input kW 0.21 0.23 0.47  
  C Condition (25°C - 27/19) Pdc kW 1.27 1.27 1.66  
    EERd   10.69 10.55 7.88  
    Power input kW 0.12 0.12 0.21  
  D Condition (20°C - 27/19) Pdc kW 1.36 1.37 1.46  
    EERd   14.25 14.16 13.76  
    Power input kW 0.10 0.10 0.11  
Space heating (Average climate) Capacity Pdesign kW 2.10 2.70 3.00  
  Energy efficiency class   A++ A++ A++  
  SCOP/A   4.61 4.60 4.60  
  SCOPnet/A   4.65 4.66 4.64  
  Pdh Heating capacity at -10° kW 1.80 2.18 2.61  
  Annual energy consumption kWh/a 638 822 913  
  Required back up heating cap at design conditions kW 0.30 0.52 0.39  
  TOL Tol (temperature operating limit) °C -15 -15 -15  
    Pdh (declared heating cap) kW 1.68 1.95 2.56  
    COPd (declared COP)   2.69 2.47 2.41  
    Power input kW 0.62 0.79 1.06  
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7  
    Pdh (declared heating cap) kW 1.87 2.31 2.64  
    COPd (declared COP)   3.40 3.10 3.10  
    Power input kW 0.55 0.75 0.85  
  A Condition (-7°C) Pdh (declared heating cap) kW 1.87 2.31 2.64  
    COPd (declared COP)   3.40 3.10 3.10  
    Power input kW 0.55 0.75 0.85  
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.40 1.53  
    COPd (declared COP)   4.89 4.87 4.80  
    Power input kW 0.22 0.29 0.32  
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 1.00 1.07  
    COPd (declared COP)   5.37 5.37 5.40  
    Power input kW 0.19 0.19 0.20  
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.96 0.99  
    COPd (declared COP)   6.36 6.36 6.42  
    Power input kW 0.15 0.15 0.15  
Space heating (Warm climate) Capacity Pdesignh kW 1.07 1.40 1.53  
  Energy efficiency class   A++ A+++ A+++  
  SCOP   5.00 5.21 5.32  
  SCOPnet   5.11 5.30 5.41  
  Annual energy consumption kWh/a 300 376 403  
  Required back up heating cap at design conditions kW 0.00 0.00 0.00  
  TOL Tol (temperature operating limit) °C -15 -15 -15  
    Pdh (declared heating cap) kW 1.68 1.95 2.56  
    COPd (declared COP)   2.69 2.47 2.41  
    Power input kW 0.62 0.79 1.06  
  TBivalent Tbiv (bivalent temperature) °C 2 2 2  
    Pdh (declared heating cap) kW 1.07 1.40 1.53  
    COPd (declared COP)   4.89 4.87 4.80  
    Power input kW 0.22 0.29 0.32  
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.40 1.53  
    COPd (declared COP)   4.89 4.87 4.80  
    Power input kW 0.22 0.29 0.32  
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 1.00 1.07  
    COPd (declared COP)   5.37 5.37 5.40  
    Power input kW 0.19 0.19 0.20  
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.96 0.99  
    COPd (declared COP)   6.36 6.36 6.42  
    Power input kW 0.15 0.15 0.15  
Pto (Thermostat off) W 9.0 9.0 9.0 9.0
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0 0.0  
  Off mode POFF W 1.0 1.0 1.0  
  Standby mode Cooling PSB W 1.0 1.0 1.0  
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25  
Heating Cdh (Degradation heating)   0.25 0.25 0.25  
Cooling function included Yes Yes Yes  
Heating function included Yes Yes Yes  
Average climate included Yes Yes Yes  
Cold season included No No No  
Warm season included No No No  
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61 63 63
  Sound power level indoor Cooling Nom. dBA 54 54 59 60
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Poff (Off mode) W       1.0
Cooling Psb (Standby mode cooling) W       1.0
  Cdc (Degradation cooling)       0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW       4.80
    Annual energy consumption kWh       239
    Energy efficiency class       7.02
    D Condition (20°C - 27/19) Pdc kW       2.17
      power input kW       0.18
      EERd       12.00
    C Condition (25°C - 27/19) power input kW       0.27
      Pdc kW       2.36
      EERd       8.64
    A Condition (35°C - 27/19) power input kW       1.43
      Pdc kW       4.80
      EERd       3.35
    B Condition (30°C - 27/19) Pdc kW       3.47
      power input kW       0.66
      EERd       5.24
  Heating (Average climate) Annual energy consumption kWh       1,505
    Pdh Heating capacity at -10° kW       4.16
    Pdesign kW       4.60
    Required back up heating cap at design conditions kW       0.44
    SCOPnet/A       A+
    TBivalent Pdh (declared heating cap) kW       4.19
      Power input kW       1.70
      Tbiv (bivalent temperature) °C       -7
      COPd (declared COP)       2.47
    C Condition (7°C) Pdh (declared heating cap) kW       1.63
      Power input kW       0.31
      COPd (declared COP)       5.24
    TOL Tol (temperature operating limit) °C       -15
      Pdh (declared heating cap) kW       4.12
      Power input kW       1.91
      COPd (declared COP)       2.16
    A Condition (-7°C) Pdh (declared heating cap) kW       4.19
      Power input kW       1.70
      COPd (declared COP)       2.47
    D Condition (12°C) Pdh (declared heating cap) kW       1.87
      Power input kW       0.24
      COPd (declared COP)       7.95
    B Condition (2°C) Power input kW       0.56
      Pdh (declared heating cap) kW       2.49
      COPd (declared COP)       4.41
  Heating (Warm climate) Required back up heating cap at design conditions kW       0.00
    Annual energy consumption kWh       604
    Pdesignh kW       2.49
    SCOPnet       A+++
    D Condition (12°C) Pdh (declared heating cap) kW       1.9
      Power input kW       0.24
      COPd (declared COP)       7.95
    TBivalent Tbiv (bivalent temperature) °C       2
      Pdh (declared heating cap) kW       2.49
      Power input kW       0.56
      COPd (declared COP)       4.41
    TOL Pdh (declared heating cap) kW       4.12
      Power input kW       1.91
      Tol (temperature operating limit) °C       -15
      COPd (declared COP)       2.16
    B Condition (2°C) Pdh (declared heating cap) kW       2.49
      Power input kW       0.56
      COPd (declared COP)       4.41
    C Condition (7°C) Power input kW       0.31
      Pdh (declared heating cap) kW       1.63
      COPd (declared COP)       5.24
Pck (Crankcase heater mode) W       0.0
Nominal efficiency Energy labeling Directive Heating       A
  COP       3.35
Heating Cdh (Degradation heating)       0.25
Cold season included       Yes