Specifications Table for FTXM-N / RXM-N9

FTXM20N2V1B / RXM20N2V1B9 FTXM20N2V1B / RXM20N5V1B9 FTXM25N2V1B / RXM25N2V1B9 FTXM25N2V1B / RXM25N5V1B9 FTXM35N2V1B / RXM35N2V1B9 FTXM35N2V1B / RXM35N5V1B9 FTXM42N2V1B / RXM42N2V1B9 FTXM50N2V1B / RXM50N2V1B9 FTXM60N2V1B / RXM60N2V1B9
Cooling capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40 1.70 1.70 1.70
  Nom. kW 2.00 2.00 2.50 2.50 3.40 3.40 4.20 5.00 6.00
  Max. kW 2.60 2.60 3.20 3.20 4.00 4.00 5.00 6.00 7.00
Heating capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40 1.70 1.70 1.70
  Nom. kW 2.50 2.50 2.80 2.80 4.00 4.00 5.40 5.80 7.00
  Max. kW 3.50 3.50 4.70 4.70 5.20 5.20 6.00 7.70 8.00
Nominal efficiency EER   4.57 4.57 4.50 4.50 4.23 4.23 4.33 3.68 3.39
  COP   5.00 5.00 5.00 5.00 4.04 4.04 4.12 4.00 3.61
  Annual energy consumption kWh 219 219 278 278 402 402 485 679 885
  Energy labeling Directive Cooling   A A A A A A A A A
    Heating   A A A A A A A A A
Space cooling Capacity Pdesign kW 2.00 2.00 2.50 2.50 3.40 3.40 4.20 5.00 6.00
  Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++
  SEER   8.65 8.65 8.65 8.65 8.65 8.65 7.85 7.41 6.90
  Annual energy consumption kWh/a 81 81 101 101 138 138 187 236 304
Space heating (Average climate) Capacity Pdesign kW 2.30 2.30 2.40 2.40 2.50 2.50 4.00 4.60 4.80
  Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A+
  SCOP/A   5.10 5.10 5.10 5.10 5.10 5.10 4.71 4.71 4.30
  Pdh Heating capacity at -10° kW 2.24 2.24 2.30 2.30 2.35 2.35 3.67 4.09 4.11
  Annual energy consumption kWh/a 632 632 659 659 687 687 1,189 1,369 1,562
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.