Specifications Table for FTXS-G / RXS-G

FTXS20G2V1B / RXS20G2V1B FTXS25G2V1B / RXS25G2V1B FTXS35G2V1B / RXS35G2V1B FTXS42G2V1B / RXS42G2V1B FTXS50G2V1B / RXS50G2V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.0 (1) 2.5 (1) 3.5 (1) 4.2 (1) 5.0 (1)
  Max. kW 2.8 3.2 4.0 5.0 5.3
Heating capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.7 (2) 3.4 (2) 4.0 (2) 5.4 (2) 5.8 (2)
  Max. kW 4.3 4.7 5.2 6.0 6.5
Nominal efficiency EER   4.26 4.55 4.02 3.44 3.29
  COP   4.29 4.53 4.17 3.67 3.69
  Annual energy consumption kWh 235 275 435 610 760
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Notes (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (3) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load