FTXS20K2V1B / RXS20L2V1B FTXS25K2V1B / RXS25L2V1B FTXS35K2V1B / RXS35L2V1B FTXS42K3V1B / RXS42L2V1B FTXS42K2V1B / RXS42L2V1B FTXS50K3V1B / RXS50L2V1B FTXS50K2V1B / RXS50L2V1B
Poff (Off mode) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Cooling Psb (Standby mode cooling) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25        
Moisture removal Cooling l/h       2.3   2.8  
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
    Annual energy consumption kWh 95 111 164 216 216 257 257
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 7.40 7.90 7.47 6.80 6.80 6.80 6.80
    D Condition (20°C - 27/19) Pdc kW 1.29 1.28 1.46 2.17 2.17 2.14 2.14
      power input kW       0.20   0.19  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.65 12.71 12.51 10.69 10.69 11.10 11.10
    C Condition (25°C - 27/19) power input kW       0.24   0.29  
      Pdc kW 1.22 1.22 1.66 2.09 2.09 2.43 2.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.32 9.98 9.17 8.80 8.80 8.48 8.48
    A Condition (35°C - 27/19) power input kW       1.25   1.51  
      Pdc kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.39 4.21 3.89 3.35 3.35 3.32 3.32
    B Condition (30°C - 27/19) Pdc kW 1.47 1.84 2.58 3.09 3.09 3.68 3.68
      power input kW       0.56   0.68  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.99 6.71 6.10 5.47 5.47 5.38 5.38
  Heating (Average climate) Annual energy consumption kWh 675 732 1,039 1,334 1,334 1,535 1,535
    Pdesign kW 2.30 2.50 3.60 4.00 4.00 4.60 4.60
    Required back up heating cap at design conditions kW 0.11 0.15 0.55 0.32 0.32 0.52 0.52
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A++ A++ A+ A+ A+ A+
    TBivalent Pdh (declared heating cap) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Power input kW       1.45   1.72  
      Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    C Condition (7°C) Pdh (declared heating cap) kW 0.99 1.00 1.25 1.66 1.66 1.62 1.62
      Power input kW       0.30   0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.96 5.96 6.42 5.59 5.59 5.35 5.35
    TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15
      Pdh (declared heating cap) kW 2.47 2.59 2.84 3.90 3.90 4.11 4.11
      Power input kW       1.91   1.94  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.52 2.50 2.33 2.04 2.04 2.12 2.12
    A Condition (-7°C) Pdh (declared heating cap) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Power input kW       1.45   1.72  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    D Condition (12°C) Pdh (declared heating cap) kW 1.32 1.34 1.09 1.84 1.84 1.95 1.95
      Power input kW       0.28   0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.10 7.10 7.79 6.59 6.59 6.43 6.43
    B Condition (2°C) Power input kW       0.49   0.56  
      Pdh (declared heating cap) kW 1.23 1.35 1.95 2.15 2.15 2.48 2.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.00 5.00 4.95 4.38 4.38 4.44 4.44
Cooling capacity Nom. Btu/h 6,800 8,500 11,900 14,300 (2) 14,300 17,100 (2) 17,100
  Min. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/h 1,720 2,150 3,010 3,610 (2) 3,610 4,300 (2) 4,300
  Max. kW 2.8 3.2 4.0 5.0 5.0 5.3 5.3
  Min. kcal/h 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Min. Btu/h 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. kW 2.00 2.5 3.5 4.20 (2) 4.20 5.00 (2) 5.00
  Max. Btu/h 9,600 10,900 13,600 17,100 17,100 18,100 18,100
  Max. kcal/h 2,410 2,750 3,440 4,300 4,300 4,560 4,560
Pck (Crankcase heater mode) W 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Nominal efficiency Annual energy consumption kWh 215 (0.000) 285 (0.000) 430 (0.000) 627 (0.000) 590 (0.000) 753 (0.000) 705 (0.000)
  Energy labeling Directive Heating A A A A A A A
  Nominal efficiency-=-Cop 4.65 4.39 4.07 3.35 (1) 3.56 3.32 (1) 3.55
Heating Heating-=-Heating cdh degradation heating 0.25 0.25 0.25        
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 12.7 9.5 12.7 12.7
  Drain OD mm 18 18 18 18 18 18 18
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Heating capacity Min. Btu/h 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. Btu/h 8,500 9,600 13,600 18,400 (2) 18,400 19,800 (2) 19,800
  Max. kcal/h 3,700 4,040 4,470 5,160 5,160 5,590 5,590
  Max. Btu/h 14,700 16,000 17,700 20,500 20,500 22,200 22,200
  Nom. kW 2.5 2.8 4.00 5.40 (2) 5.40 5.80 (2) 5.80
  Min. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/h 2,150 2,410 3,440 4,640 (2) 4,640 4,990 (2) 4,990
  Min. kcal/h 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Max. kW 4.3 4.7 5.2 6.0 6.0 6.5 6.5
Pto (Thermostat off) W 20.0 21.0 28.0 30.0 30.0 30.0 30.0
Power input Cooling Min. kW 0.320 0.320 0.350 0.320 0.320 0.350 0.350
    Nom. kW 0.430 0.570 0.860 1.253 (2) 1.180 1.506 (2) 1.410
    Max. kW 0.760 1.000 1.190 2.330 2.330 1.810 1.810
  Heating Max. kW 1.120 1.410 1.460 1.980 1.980 2.000 2.000
    Min. kW 0.310 0.310 0.340 0.400 0.400 0.300 0.300
    Nom. kW 0.530 0.600 0.840 1.310 (2) 1.310 1.450 (2) 1.450
Cold season included Yes Yes Yes Yes Yes Yes Yes
Current Nominal running current (RLA) - 50Hz Heating A 2.8 (2), 2.7 (3), 2.6 (4) 3.3 (2), 3.2 (3), 3.1 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.6 (3), 6.3 (4), 6.0 (5) 6.6 (2), 6.3 (3), 6.0 (4) 6.8 (3), 6.5 (4), 6.2 (5) 6.8 (2), 6.5 (3), 6.2 (4)
    Cooling A 2.4 (2), 2.3 (3), 2.2 (4) 3.2 (2), 3.1 (3), 3.0 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.37 (3), 6.05 (4), 5.84 (5) 6.0 (2), 5.7 (3), 5.5 (4) 7.05 (3), 6.73 (4), 6.41 (5) 6.6 (2), 6.3 (3), 6.0 (4)
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  220V 220V 220V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 220V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 220V
  230V 230V 230V 220V 230V 220V 230V
  240V 240V 240V 230V 240V 230V 240V
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 240V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load 240V Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Cooling Cdc (Degradation cooling)       0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)       0.25 0.25 0.25 0.25