Specifications Table for FUQ-C / RQ-BV3

FUQ71CVEB / RQ71B8V3B FUQ100CVEB / RQ100B8V3B
Cooling capacity Nom. kW 7.1 (3) 10 (3)
Nominal efficiency Annual energy consumption kWh 1,350 (0.000) 1,915 (0.000)
  Energy labeling Directive Heating D D
  Nominal efficiency-=-Cop 2.63 2.61
Heating capacity Nom. kW 8.0 (4) 11.20 (4)
Power input Cooling Nom. kW 2.70 3.83
  Heating Nom. kW 2.53 3.58
Notes Energy label: scale from A (most efficient) to G (less efficient) Energy label: scale from A (most efficient) to G (less efficient)
  Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  In accordance with EN/IEC 61000-3-11, respectively EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys ≤ Zmax, respectively Ssc ≥ minimum Ssc value. In accordance with EN/IEC 61000-3-11, respectively EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys ≤ Zmax, respectively Ssc ≥ minimum Ssc value.
  European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A. European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
  system impedance system impedance
  Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
  Short-circuit power Short-circuit power
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load