Specifications Table for LRYEQ-AY

LRYEQ16A7Y1
Casing Colour   Ivory white
Dimensions Unit Height mm 1,680
    Width mm 1,240
    Depth mm 765
Weight Unit kg 370
Compressor 2 Type   Hermetically sealed scroll compressor
Fan Type   Propeller fan
  Quantity   2
  Air flow rate Cooling Nom. m³/min 230
Fan motor Output W 750
  Drive   Direct drive
Heat exchanger Type   Cross fin coil
Refrigerant Type   R-410A
  GWP   2,087.5
  Charge kg 11.5
  Charge TCO2Eq 24.0
Standard Accessories Installation manual 1
  Operation manual 1
  Connection pipes 1
  Refrigerant label for F-gas regulation 1
  Refrigerant charge label 1
  Multilingual fluorinated greenhouse gases labels 1
Power supply Phase   3~
  Frequency Hz 50
  Voltage V 380-415
Notes Cooling priority mode: indoor temp. 27°CDB, 19°CWB; outdoor temp. 32°CDB; piping length: 7.5m; level difference: 0m
  Cooling priority mode: evaporating temp. -10°C; outdoor temp. 32°CDB; Suction SH: 10°C
  Heat recovery 100% mode: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; refrigeration load 18kW; piping length: 7.5m; level difference: 0m
  Saturated temperature equivalent to suction pressure (refrigeration side): -10°C (under chilled condition); connection capacity for indoor air conditioner: 10HP, when heat recovery is 100%
  Compressor 1
  Compressor 2
  Compressor 3
  Factory charge of unit
  Install the oil trap per 5m from the outdoor unit
  For more details, see operation range drawing
  For more details on standard accessories refer to Installation/operation manual
  Contains fluorinated greenhouse gases