Specifications Table for RXM-M

RXM20M2V1B RXM25M2V1B RXM35M2V1B RXM42MV1B RXM42M2V1B RXM50MV1B RXM50M2V1B RXM60M2V1B RXM71M2V1B
Dimensions Unit Height mm 550 550 550 735 735 735 735 735 734
    Width mm 765 765 765 825 825 825 825 825 870
    Depth mm 285 285 285 300 300 300 300 300 320
Weight Unit kg 32 32 32 47 47 44 47 44 56
Compressor Type   Hermetically sealed swing compressor   Hermetically sealed swing compressor   Hermetically sealed swing compressor   Hermetically sealed swing compressor   Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10 -10 -10 -10 -10 (1) -10 -10 (1) -10 -10 (1)
      Max. °CDB 46 46 46 46 46 (1) 46 46 (1) 46 46 (1)
  Heating Ambient Min. °CWB -15 -15 -15 -15 -15 -15 -15 -15 -15
      Max. °CWB 18 18 18 18 18 18 18 18 18
Sound power level Cooling dBA 59 59 61 63 62 63 62 63 66
  Heating dBA 59 59 61 63 62 62 62 63 67
Sound pressure level Cooling High dBA 46 46 49 48   48   48  
    Nom. dBA         48   48   47
    Low dBA           44   44  
  Heating High dBA 47 47 49 48   49   49  
    Nom. dBA         48   49   48
    Low dBA           45   45  
Refrigerant Type   R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32
  Charge kg 0.76 0.76 0.76 1.30 1.30 1.4 1.40 1.45 1.15
  Charge TCO2Eq 0.5 0.5 0.5 0.9 0.88 0.9 0.95 1.0 0.78
  GWP   675 675 675 675 675 675 675 675 675.0
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)  
  Level difference IU - OU Max. m 20 20 20 12 20 20 20 20  
Standard Accessories Drain plug (only heat pump models) 1 1 1 1 1 1 1 1 1
  Installation manual 1 1 1 1 1 1 1 1 1
  Refrigerant charge label 1 1 1 1 1 1 1 1 1
  Multilingual fluorinated greenhouse gases labels 1 1 1 1 1 1 1 1 1
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting See separate drawing for operation range SL: The silent fan level of the air flow rate setting See separate drawing for operation range SL: The silent fan level of the air flow rate setting (1) - See separate drawing for operation range
  Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases See separate drawing for electrical data Contains fluorinated greenhouse gases See separate drawing for electrical data Contains fluorinated greenhouse gases (2) - See separate drawing for electrical data
Compressor Type     Hermetically sealed swing compressor   Hermetically sealed swing compressor   Hermetically sealed swing compressor   Hermetically sealed swing compressor  
Notes         Contains fluorinated greenhouse gases   Contains fluorinated greenhouse gases   (3) - Contains fluorinated greenhouse gases
Piping connections Additional refrigerant charge kg/m                 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m                 20.0
Standard Accessories Drain cap (1)                 6
  Drain cap (2)                 3