Specifications Table for RZQG-L9V1

RZQG71L9V1B RZQG100L9V1B RZQG125L9V1B RZQG140L9V1B
Dimensions Unit Height mm 990 1,430 1,430 1,430
    Width mm 940 940 940 940
    Depth mm 320 320 320 320
Weight Unit kg 69.0 95.0 95.0 95.0
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -15.0 -15.0 -15.0 -15.0
      Max. °CDB 50.0 50.0 50.0 50.0
  Heating Ambient Min. °CWB -20.0 -20.0 -20.0 -20.0
      Max. °CWB 15.5 15.5 15.5 15.5
Sound power level Cooling dBA 64.0 66.0 67.0 69.0
  Heating dBA 64.0 66.0 67.0 69.0
Sound pressure level Cooling Nom. dBA 48 50 51 52
  Heating Nom. dBA 50 52 53 53
  Night quiet mode Level 1 dBA 43 45 45 45
Refrigerant Type   R-410A R-410A R-410A R-410A
  Charge kg 2.9 4.0 4.0 4.0
  Charge TCO2Eq 6.05 8.35 8.35 8.35
  GWP   2,087.5 2,087.5 2,087.5 2,087.5
Piping connections Liquid OD mm 9,52 9,52 9,52  
  Gas OD mm 15.9 15.9 15.9  
  Piping length OU - IU Max. m 50 75 75  
    System Equivalent m 70 90 90  
      Chargeless m 30 30 30  
  Additional refrigerant charge kg/m See installation manual See installation manual See installation manual  
  Level difference IU - OU Max. m 30.0 30.0 30.0  
    IU - IU Max. m 0.5 0.5 0.5  
Standard Accessories Tie-wraps 2 2 2 2
  Installation manual 1 1 1 1
Power supply Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Current - 50Hz Maximum fuse amps (MFA) A 25 40 40  
Notes (1) - 3 with re-charging (1) - 3 with re-charging (1) - 3 with re-charging 3 with re-charging
  (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
  (3) - Ssc: Short-circuit power (3) - Ssc: Short-circuit power (3) - Ssc: Short-circuit power Ssc: Short-circuit power
  (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data See separate drawing for electrical data
  (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
Piping connections Additional refrigerant charge kg/m       See installation manual
  Level difference IU - OU Max. m       30.0
    IU - IU Max. m       0.5