ATXB25C2V1B | ATXB35C2V1B | ATXB50CV1B | ATXB60CV1B | |||||
---|---|---|---|---|---|---|---|---|
Power input | Heating | Nom. | kW | 0.030 | 0.030 | |||
Casing | Colour | White | White | White | White | |||
Dimensions | Unit | Height | mm | 283 | 283 | 310 | 310 | |
Width | mm | 770 | 770 | 1,065 | 1,065 | |||
Depth | mm | 216 | 216 | 224 | 224 | |||
Weight | Unit | kg | 8 | 8 | 14 | 14 | ||
Fan | Air flow rate | Cooling | High | m³/min | 9.2 | 9.3 | ||
Low | m³/min | 6.0 | 6.1 | |||||
Silent operation | m³/min | 4.8 | 4.9 | |||||
Heating | High | m³/min | 9.7 | 10.1 | ||||
Low | m³/min | 6.3 | 6.7 | |||||
Silent operation | m³/min | 5.5 | 5.7 | |||||
Nom. | m³/min | 7.6 | 7.7 | |||||
Heating | Nom. | m³/min | 8.0 | 8.4 | ||||
Sound power level | Cooling | dBA | 55 | 58 | 55 | 61 | ||
Heating | dBA | 55 | 58 | |||||
Sound pressure level | Cooling | Super high | dBA | 44 | 46 | |||
High | dBA | 40 | 41 | 40 | 43 | |||
Low | dBA | 26 | 27 | 35 | 37 | |||
Silent operation | dBA | 21 | 23 | 32 | 33 | |||
Heating | High | dBA | 40 | 41 | 40 | 43 | ||
Low | dBA | 28 | 29 | 35 | 37 | |||
Silent operation | dBA | 25 | 26 | 32 | 33 | |||
Nom. | dBA | 33 | 34 | 38 | 41 | |||
Heating | Nom. | dBA | 34 | 35 | 38 | 41 | ||
Piping connections | Liquid | OD | mm | 6.35 | 6.35 | |||
Gas | OD | mm | 9.5 | 9.5 | ||||
Drain | 18 | 18 | 19.05 | 19.05 | ||||
Control systems | Infrared remote control | ARC470A1 | ARC470A1 | |||||
Standard Accessories | Installation manual | 1 | 1 | |||||
Operation manual | 1 | 1 | ||||||
Infrared remote control | 1 | 1 | ||||||
AA dry-cell batteries | 2 | 2 | ||||||
Remote control holder | 1 | 1 | ||||||
Mounting plate | 1 | 1 | ||||||
Titanium apatite photocatalytic air purification filter | 2 | 2 | ||||||
Indoor unit fixing screws | 2 | 2 | ||||||
Power supply | Name | V1 | V1 | V1 | V1 | |||
Phase | 1~ | 1~ | 1~ | 1~ | ||||
Frequency | Hz | 50 | 50 | 50 | 50 | |||
Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | |||
Notes | (1) - SL: The silent fan level of the air flow rate setting | (1) - SL: The silent fan level of the air flow rate setting | (1) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). | (1) - All units are being tested and comply to ISO 5151 (non-conducted unit) or ISO 1325 (ducted unit). |