Specifications Table for ATXP-L / ARXP-L

ATXP20L2V1B / ARXP20L5V1B ATXP20L5V1B / ARXP20L5V1B ATXP20L2V1B / ARXP20L2V1B ATXP25L2V1B / ARXP25L5V1B ATXP25L5V1B / ARXP25L5V1B ATXP25L2V1B / ARXP25L2V1B ATXP35L2V1B / ARXP35L5V1B ATXP35L5V1B / ARXP35L5V1B ATXP35L2V1B / ARXP35L2V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
  Nom. kW 2.00 2.00 2.00 2.50 2.50 2.50 3.50 3.50 3.50
  Max. kW 2.6 2.6 2.6 3.0 3.0 3.0 4.0 4.0 4.0
Heating capacity Min. kW 1.30 1.30 1.30 1.30 1.30 1.30 1.30 1.30 1.30
  Nom. kW 2.50 2.50 2.50 3.00 3.00 3.00 4.00 4.00 4.00
  Max. kW 3.50 3.50 3.50 4.00 4.00 4.00 4.80 4.80 4.80
Nominal efficiency EER   3.98 3.98 3.98 3.79 3.79 3.79 3.45 3.45 3.45
  COP   4.77 4.77 4.77 4.36 4.36 4.36 4.02 4.02 4.02
  Energy labeling Directive Cooling   A A A A A A A A A
    Heating   A A A A A A A A A
Space cooling Capacity Pdesign kW 2.00 2.00 2.00   2.50 2.50   3.50 3.50
  Energy efficiency class   A++ A++ A++   A++ A++   A++ A++
  SEER   6.77 6.77 6.77   6.85 6.85   6.56 6.56
  Annual energy consumption kWh/a 104 104 104   128 128   187 187
Space heating (Average climate) Capacity Pdesign kW 2.20 2.20 2.20   2.40 2.40   2.80 2.80
  Energy efficiency class   A++ A++ A++   A++ A++   A++ A++
  SCOP/A   4.64 4.64 4.64   4.60 4.60   4.62 4.62
  Pdh Heating capacity at -10° kW 1.98 1.98     2.09     2.32  
  Annual energy consumption kWh/a 663 663 663   730 730   847 847
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data