Specifications Table for AZQS-B(8)V1 A

AZQS71B2V1B A AZQS100B8V1B A AZQS125B8V1B A AZQS140B8V1B A
Dimensions Unit Height Mm 770 990 990 1,430
    Width Mm 900 940 940 940
    Depth Mm 320 320 320 320
Weight Unit kg 67 72.8 74.3 94.9
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Sound power level Cooling dBA 64 70 71 70
Sound pressure level Cooling Nom. dBA 48 53 54 53
  Heating Nom. dBA 50 57 58 54
  Night quiet mode Level 1 dBA 43 49 49 49
Refrigerant Type   R-410A R-410A R-410A R-410A
  Charge kg 2.75 2.9 2.9 4.0
  Charge TCO2Eq 5.7 6.1 6.1 8.4
  GWP   2,087.5 2,087.5 2,087.5 2,087.5
Piping connections Liquid OD Mm 9.52 9.52 9.52 9.52
  Gas OD Mm 15.9 15.9 15.9 15.9
  Piping length OU - IU Max. m 30 30 30 30
    System Equivalent m 40 40 40 40
      Chargeless m 30 30 30 30
  Additional refrigerant charge kg/m See installation manual See installation manual See installation manual See installation manual
  Level difference IU - OU Max. m 30.0 30.0 30.0 30.0
    IU - IU Max. m   0.5 0.5 0.5
Standard Accessories Tie-wraps 2 2 2 2
  Installation manual 1 1 1 1
Power supply Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (3) - See separate drawing for electrical data (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (4) - Contains fluorinated greenhouse gases (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2
    (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data (5) - See separate drawing for electrical data
    (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases
    (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
    (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series