EBHQ011BB6V3 (Archived) |
EBHQ014BB6V3 (Archived) |
EBHQ016BB6V3 (Archived) |
Heating capacity |
Nom. |
kW |
11.2 (1), 10.9 (2) |
14.0 (1), 13.1 (2) |
16.0 (1), 15.1 (2) |
Cooling capacity |
Nom. |
kW |
12.9 (1), 10.0 (2) |
16.0 (1), 12.5 (2) |
16.7 (1), 13.1 (2) |
Power input |
Cooling |
Nom. |
kW |
3.87 (1), 3.69 (2) |
5.75 (1), 5.39 (2) |
6.36 (1), 5.93 (2) |
|
Heating |
Nom. |
kW |
2.56 (1), 3.31 (2) |
3.29 (1), 4.01 (2) |
3.88 (1), 4.71 (2) |
COP |
4.38 (1), 3.28 (2) |
4.25 (1), 3.27 (2) |
4.12 (1), 3.20 (2) |
EER |
3.32 (1), 2.71 (2) |
2.78 (1), 2.32 (2) |
2.63 (1), 2.21 (2) |
Dimensions |
Unit |
Height |
mm |
1,418 |
1,418 |
1,418 |
|
|
Width |
mm |
1,435 |
1,435 |
1,435 |
|
|
Depth |
mm |
382 |
382 |
382 |
Weight |
Unit |
kg |
180 |
180 |
180 |
Fan |
Air flow rate |
Heating |
High |
m³/min |
90.0 |
90.0 |
90.0 |
|
|
Cooling |
High |
m³/min |
96.0 |
100 |
97.0 |
Operation range |
Heating |
Ambient |
Min. |
°CWB |
-20 |
-20 |
-20 |
|
|
|
Max. |
°CWB |
40 |
40 |
40 |
|
|
Water side |
Min. |
°C |
15 (3) |
15 (3) |
15 (3) |
|
|
|
Max. |
°C |
55.0 (3) |
55.0 (3) |
55.0 (3) |
|
Cooling |
Ambient |
Min. |
°CDB |
10.0 |
10.0 |
10.0 |
|
|
|
Max. |
°CDB |
46.0 |
46.0 |
46.0 |
|
|
Water side |
Min. |
°C |
5.00 |
5.00 |
5.00 |
|
|
|
Max. |
°C |
22.0 |
22.0 |
22.0 |
|
Domestic hot water |
Ambient |
Min. |
°CDB |
-15.0 |
-15.0 |
-15.0 |
|
|
|
Max. |
°CDB |
43.0 |
43.0 |
43.0 |
|
|
Water side |
Min. |
°C |
25 |
25 |
25 |
|
|
|
Max. |
°C |
80 |
80 |
80 |
Sound power level |
Heating |
Nom. |
dBA |
60 |
70 |
70 |
|
Cooling |
Nom. |
dBA |
65.0 |
66.0 |
69.0 |
Sound pressure level |
Heating |
Nom. |
dBA |
50 (4) |
50 (4) |
50 (4) |
|
Cooling |
Nom. |
dBA |
50 (4) |
50 (4) |
50 (4) |
Refrigerant |
Type |
|
R-410A |
R-410A |
R-410A |
|
GWP |
|
2,087.5 |
2,087.5 |
2,087.5 |
|
Charge |
kg |
3.0 |
3.0 |
3.0 |
|
Charge |
TCO2Eq |
6.2 |
6.2 |
6.2 |
Space heating |
Average climate water outlet 55°C |
General |
SCOP |
|
2.70 |
2.71 |
2.60 |
|
|
|
Seasonal space heating eff. class |
|
A+ |
A+ |
A+ |
|
|
|
ηs (Seasonal space heating efficiency) |
% |
105 |
105 |
101 |
|
Average climate water outlet 35°C |
General |
SCOP |
|
3.30 |
3.32 |
3.15 |
|
|
|
Seasonal space heating eff. class |
|
A+ |
A+ |
A+ |
|
|
|
ηs (Seasonal space heating efficiency) |
% |
129 |
130 |
123 |
Compressor component |
Main power supply |
Name |
|
V3 |
V3 |
V3 |
|
|
Phase |
|
1~ |
1~ |
1~ |
|
|
Frequency |
Hz |
50 |
50 |
50 |
|
|
Voltage |
V |
230 |
230 |
230 |
|
Current |
Recommended fuses |
A |
32.0 |
32.0 |
32.0 |
Notes |
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
|
(3) - 15°C-25°C: BUH only, no heat pump operation = during commissioning |
(3) - 15°C-25°C: BUH only, no heat pump operation = during commissioning |
(3) - 15°C-25°C: BUH only, no heat pump operation = during commissioning |
|
(4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. |
(4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. |
(4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. |
|
(5) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(5) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(5) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(6) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) |
(6) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) |
(6) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) |
|
(7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) |
(7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) |
(7) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) |
|
(8) - Tamb 35°C - LWE 18°C (DT=5°C) |
(8) - Tamb 35°C - LWE 18°C (DT=5°C) |
(8) - Tamb 35°C - LWE 18°C (DT=5°C) |
|
(9) - Including piping + PHE + back-up heater; excluding expansion vessel |
(9) - Including piping + PHE + back-up heater; excluding expansion vessel |
(9) - Including piping + PHE + back-up heater; excluding expansion vessel |
|
(10) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. |
(10) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. |
(10) - Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra water volume might be required. Refer to operation range for more info. |