EKHBRD011ADV17 |
EKHBRD014ADV17 |
EKHBRD016ADV17 |
Casing |
Colour |
|
Metallic grey |
Metallic grey |
Metallic grey |
|
Material |
|
Precoated sheet metal |
Precoated sheet metal |
Precoated sheet metal |
Dimensions |
Unit |
Height |
mm |
705 |
705 |
705 |
|
|
Width |
mm |
600 |
600 |
600 |
|
|
Depth |
mm |
695 |
695 |
695 |
Weight |
Unit |
kg |
144 |
144 |
144 |
PED |
Category |
|
Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
Excluded from scope of PED due to article 1, item 3.6 of 97/23/EC |
Refrigerant |
Type |
|
R-134a |
R-134a |
R-134a |
|
Charge |
kg |
2.60 |
2.60 |
2.60 |
Sound power level |
Nom. |
dBA |
59.0 (3) |
60.0 (3) |
60.0 (3) |
Sound pressure level |
Nom. |
dBA |
43.0 (4), 46.0 (5), 0.00 (6), 0.00 (7) |
45.0 (4), 46.0 (5), 0.00 (6), 0.00 (7) |
46.0 (4), 46.0 (5), 0.00 (6), 0.00 (7) |
Operation range |
Heating |
Water side |
Min. |
°C |
25 |
25 |
25 |
|
|
|
Max. |
°C |
80.0 |
80.0 |
80.0 |
Power supply |
Name |
|
V1 |
V1 |
V1 |
|
Phase |
|
1~ |
1~ |
1~ |
|
Frequency |
Hz |
50 |
50 |
50 |
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
Current |
Recommended fuses |
A |
25 |
25 |
25 |
Notes |
(1) - Nominal water flow rate for Dt: 10°C |
(1) - Nominal water flow rate for Dt: 10°C |
(1) - Nominal water flow rate for Dt: 10°C |
|
(2) - Maximum water flow rate for Dt: 5°C |
(2) - Maximum water flow rate for Dt: 5°C |
(2) - Maximum water flow rate for Dt: 5°C |
|
(3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. |
(3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. |
(3) - Sound pressure level is measured in accordance with ISO3744. Sound power level is calculated from sound pressure level. |
|
(4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
(4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
(4) - Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
|
(5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
(5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
(5) - Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB |
|
(6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. |
(6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. |
(6) - Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental noise and sound reflections. |
|
(7) - EW = entering water temperature - LW = leaving water temperature |
(7) - EW = entering water temperature - LW = leaving water temperature |
(7) - EW = entering water temperature - LW = leaving water temperature |
|
(8) - Outdoor ambient, indoor ambient: 5°C~30°C |
(8) - Outdoor ambient, indoor ambient: 5°C~30°C |
(8) - Outdoor ambient, indoor ambient: 5°C~30°C |
|
(9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C |
(9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C |
(9) - For details see operation range TW drawing. In combination EKHBRD* + EMRQ* see EMRQ* operation range! -> -15°C |
|
(10) - 1kW = 859.84522786 kcal/h; 1kW = 3,412.14163313 BTU/h; 1kW = 0.28434514 TR |
(10) - 1kW = 859.84522786 kcal/h; 1kW = 3,412.14163313 BTU/h; 1kW = 0.28434514 TR |
(10) - 1kW = 859.84522786 kcal/h; 1kW = 3,412.14163313 BTU/h; 1kW = 0.28434514 TR |
|
(11) - 220V |
(11) - 220V |
(11) - 220V |
|
(12) - 240V |
(12) - 240V |
(12) - 240V |
|
(13) - 50Hz, 220-230-240V |
(13) - 50Hz, 220-230-240V |
(13) - 50Hz, 220-230-240V |
|
(14) - 60Hz, 220-230V |
(14) - 60Hz, 220-230V |
(14) - 60Hz, 220-230V |
|
(15) - A filter strainer must be added in the water circuit of the evaporator (field installation). A flow switch must be provided at the evaporator side. Min. water volume applicable at nominal conditions. |
(15) - A filter strainer must be added in the water circuit of the evaporator (field installation). A flow switch must be provided at the evaporator side. Min. water volume applicable at nominal conditions. |
(15) - A filter strainer must be added in the water circuit of the evaporator (field installation). A flow switch must be provided at the evaporator side. Min. water volume applicable at nominal conditions. |