EPGA11DAV37 |
EPGA14DAV37 |
EPGA16DAV37 |
Dimensions |
Unit |
Height |
mm |
1,440 |
1,440 |
1,440 |
|
|
Width |
mm |
1,160 |
1,160 |
1,160 |
|
|
Depth |
mm |
380 |
380 |
380 |
Weight |
Unit |
kg |
143 |
143 |
143 |
Operation range |
Cooling |
Min. |
°CDB |
10 |
10 |
10 |
|
|
Max. |
°CDB |
43 |
43 |
43 |
|
Domestic hot water |
Max. |
°CDB |
35 |
35 |
35 |
|
|
Min. |
°CDB |
-28 |
-28 |
-28 |
Piping connections |
Level difference |
IU - OU |
Max. |
m |
10.0 |
10.0 |
10.0 |
Sound power level |
Heating |
Nom. |
dBA |
64.0 (1) |
64.0 (1) |
66.0 (1) |
|
Cooling |
Nom. |
dBA |
68.0 (1) |
68.0 (1) |
68.0 (1) |
Sound pressure level |
Heating |
Nom. |
dBA |
48.0 (2) |
49.0 (2) |
52.0 (2) |
|
Cooling |
Nom. |
dBA |
55.0 (3) |
55.0 (3) |
55.0 (3) |
Refrigerant |
Type |
|
R-32 |
R-32 |
R-32 |
|
GWP |
|
675.0 |
675.0 |
675.0 |
|
Charge |
TCO2Eq |
2.36 |
2.36 |
2.36 |
|
Charge |
kg |
3.50 |
3.50 |
3.50 |
Power supply |
Name |
|
V3 |
V3 |
V3 |
|
Phase |
|
1N~ |
1N~ |
1N~ |
|
Frequency |
Hz |
50 |
50 |
50 |
|
Voltage |
V |
230 |
230 |
230 |
Current |
Recommended fuses |
A |
32 |
32 |
32 |
Notes |
(1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 |
(2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 |
(2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 |
|
(3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = |
(3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = |
(3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = |