FTXJ20A2V1BS / RXJ20A5V1B |
FTXJ25A2V1BS / RXJ25A5V1B |
FTXJ35A2V1BS / RXJ35A5V1B |
FTXJ42A2V1BS / RXJ42A2V1B |
FTXJ50A2V1BS / RXJ50A2V1B |
Cooling capacity |
Min. |
kW |
1.30 |
1.30 |
1.40 |
1.70 |
1.70 |
|
Nom. |
kW |
2.00 |
2.50 |
3.40 |
4.20 |
5.00 |
|
Max. |
kW |
2.60 |
3.20 |
4.00 |
5.00 |
5.30 |
Heating capacity |
Min. |
kW |
1.30 |
1.30 |
1.40 |
1.70 |
1.70 |
|
Nom. |
kW |
2.50 |
2.80 |
4.00 |
5.40 |
5.80 |
|
Max. |
kW |
3.50 |
4.70 |
5.20 |
6.00 |
6.50 |
Nominal efficiency |
Annual energy consumption |
kWh |
213 |
280 |
389 |
526 |
679 |
|
COP |
|
5.00 |
5.00 |
4.04 |
4.12 |
4.00 |
|
EER |
|
4.70 |
4.46 |
4.37 |
3.99 |
3.68 |
|
Energy labeling Directive |
Cooling |
|
A |
A |
A |
A |
A |
|
|
Heating |
|
A |
A |
A |
A |
A |
Space cooling |
Annual energy consumption |
kWh/a |
80 |
100 |
136 |
196 |
239 |
|
Energy efficiency class |
|
A+++ |
A+++ |
A+++ |
A++ |
A++ |
|
Capacity |
Pdesign |
kW |
2.00 |
2.50 |
3.40 |
4.20 |
5.00 |
|
SEER |
|
8.75 |
8.74 |
8.73 |
7.50 |
7.33 |
Space heating (Average climate) |
Annual energy consumption |
kWh/a |
652 |
666 |
680 |
1,156 |
1,218 |
|
Capacity |
Pdesign |
kW |
2.40 |
2.45 |
2.50 |
3.80 |
4.00 |
|
Energy efficiency class |
|
A+++ |
A+++ |
A+++ |
A++ |
A++ |
|
Pdh Heating capacity at -10° |
kW |
2.02 |
2.07 |
2.11 |
3.26 |
3.44 |
|
SCOP/A |
|
5.15 |
5.15 |
5.15 |
4.60 |
4.60 |
Notes |
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
(1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. |
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. |
|
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
(3) - See separate drawing for operation range |
|
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |
(4) - See separate drawing for electrical data |