Specifications Table for FTXS-K / RXL-K

FTXS20K2V1B / RXL20K3V1B FTXS25K2V1B / RXL25K3V1B FTXS35K2V1B / RXL35K2V1B FTXS42K2V1B / RXL42K2V1B FTXS50K2V1B / RXL50K2V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.0 (2) 2.5 (2) 3.5 (2) 4.2 (2) 5.0 (2)
  Max. kW 2.8 3.2 4.0 5.0 5.3
Heating capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.5 (3) 2.8 (3) 4.0 (3) 5.4 (3) 5.8 (3)
  Max. kW 4.3 4.7 5.2 6.0 6.5
Nominal efficiency EER   4.65 (1) 4.39 (1) 4.07 (1) 3.56 (1) 3.55 (1)
  COP   4.55 (1) 4.52 (1) 4.76 (1) 4.12 (1) 4.00 (1)
  Annual energy consumption kWh 215 285 420 590 750
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Space cooling Capacity Pdesign kW 2.00 2.50 3.50 4.20 5.00
  Energy efficiency class   A+ A++ A++ A++ A++
  SEER   5.70 6.37 7.08 6.67 6.72
  Annual energy consumption kWh/a 123 137 173 220 261
Space heating (Average climate) Capacity Pdesign kW 2.30 2.50 3.60 4.00 4.60
  Energy efficiency class   A++ A+ A++ A+ A+
  SCOP/A   4.62 4.51 4.63 4.03 4.06
  Annual energy consumption kWh/a 698 775 1,087 1,389 1,586
Piping connections Drain OD mm 18.0 18.0 18.0 18.0 18.0
  Gas OD mm 9.5 9.5 9.5 9.5 12.7
  Liquid OD mm 6.35 6.35 6.35 6.35 6.35
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - 220V (4) - 220V (4) - 220V (4) - 220V (4) - 220V
  (5) - 230V (5) - 230V (5) - 230V (5) - 230V (5) - 230V
  (6) - 240V (6) - 240V (6) - 240V (6) - 240V (6) - 240V
  (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load