FVXG25K2V1B / RXG25K2V1B |
FVXG25K2V1B / RXG25K3V1B |
FVXG35K2V1B / RXG35K2V1B |
FVXG35K2V1B / RXG35K3V1B |
FVXG50K2V1B / RXG50K2V1B |
FVXG50K2V1B / RXG50K3V1B |
Cooling capacity |
Min. |
kW |
1.3 |
1.3 |
1.4 |
1.4 |
1.7 |
1.7 |
|
Nom. |
kW |
2.5 (3) |
2.5 (2) |
3.5 (3) |
3.5 (2) |
5.0 (3) |
5.0 (2) |
|
Max. |
kW |
3.0 |
3.0 |
3.8 |
3.8 |
5.6 |
5.6 |
Heating capacity |
Min. |
kW |
1.3 |
1.3 |
1.4 |
1.4 |
1.7 |
1.7 |
|
Nom. |
kW |
3.4 (4) |
3.4 (3) |
4.5 (4) |
4.5 (3) |
5.8 (4) |
5.8 (3) |
|
Max. |
kW |
4.5 |
4.5 |
5.0 |
5.0 |
8.1 |
8.1 |
Nominal efficiency |
EER |
|
4.55 |
4.55 |
3.68 |
3.68 |
3.29 |
3.29 |
|
COP |
|
4.36 |
4.36 |
3.72 |
3.72 |
3.67 |
3.67 |
|
Annual energy consumption |
kWh |
275 |
275 |
475 |
475 |
760 |
760 |
|
Energy labeling Directive |
Cooling |
|
A |
A |
A |
A |
A |
A |
|
|
Heating |
|
A |
A |
A |
A |
A |
A |
Space cooling |
Capacity |
Pdesign |
kW |
|
2.50 |
|
3.50 |
|
5.00 |
|
Energy efficiency class |
|
A++ |
|
A++ |
|
A |
|
SEER |
|
6.46 |
|
6.33 |
|
5.31 |
|
Annual energy consumption |
kWh/a |
|
135 |
|
194 |
|
330 |
Space heating (Average climate) |
Capacity |
Pdesign |
kW |
|
2.80 |
|
3.10 |
|
4.60 |
|
Energy efficiency class |
|
A+ |
|
A |
|
A+ |
|
SCOP/A |
|
4.56 |
|
3.93 |
|
4.13 |
|
Annual energy consumption |
kWh/a |
|
858 |
|
1,103 |
|
1,559 |
Piping connections |
Drain |
OD |
mm |
18 |
18 |
18 |
18 |
18 |
18 |
|
Gas |
OD |
mm |
9.5 |
9.5 |
9.5 |
9.5 |
12.7 |
12.7 |
|
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
Notes |
(1) - Energy label: scale from A (most efficient) to G (less efficient) |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
(1) - Energy label: scale from A (most efficient) to G (less efficient) |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
(1) - Energy label: scale from A (most efficient) to G (less efficient) |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
|
(2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) |
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) |
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) |
(2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
|
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
|
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB |
(3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
|
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(4) - 220V |
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(4) - 220V |
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(4) - 220V |
|
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(5) - 230V |
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(5) - 230V |
(4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB |
(5) - 230V |
|
(5) - 220V |
(6) - 240V |
(5) - 220V |
(6) - 240V |
(5) - 220V |
(6) - 240V |
|
(6) - 230V |
(7) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
(6) - 230V |
(7) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
(6) - 230V |
(7) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
|
(7) - 240V |
(8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
(7) - 240V |
(8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
(7) - 240V |
(8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
|
(8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
|
(8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
|
(8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. |
|
|
(9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
|
(9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
|
(9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
|