FWD04AATN6V3 |
FWD04ACTN6V3 |
FWD06AATN6V3 |
FWD06ACTN6V3 |
FWD08AATN6V3 |
FWD08ACTN6V3 |
FWD10AATN6V3 |
FWD10ACTN6V3 |
FWD12AATN6V3 |
FWD12ACTN6V3 |
FWD16AATN6V3 |
FWD16ACTN6V3 |
FWD18AATN6V3 |
FWD18ACTN6V3 |
Sound pressure level |
Low |
dBA |
|
49 (5) |
|
54 (5) |
|
57 (5) |
|
57 (5) |
|
55 (5) |
|
64 (5) |
|
64 (5) |
|
High |
dBA |
|
61 (5) |
|
64 (5) |
|
67 (5) |
|
67 (5) |
|
69 (5) |
|
73 (5) |
|
73 (5) |
Water pressure drop |
Heating |
Rated |
kPa |
14 |
|
20 |
|
20 |
|
13 |
|
21 |
|
28 |
|
37 |
|
|
Cooling |
Rated |
kPa |
17 |
|
24 |
|
24 |
|
16 |
|
26 |
|
34 |
|
45 |
|
Control systems |
Wired remote control |
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
FWEC1A, FWEC2A, FWEC3A |
|
Total sound power level |
Low |
dBA |
|
54 (4) |
|
59 (4) |
|
62 (4) |
|
62 (4) |
|
60 (4) |
|
69 (4) |
|
69 (4) |
|
High |
dBA |
|
66 (4) |
|
69 (4) |
|
72 (4) |
|
72 (4) |
|
74 (4) |
|
78 (4) |
|
78 (4) |
Water flow |
Cooling |
Low |
l/h |
|
493 (1) |
|
915 (1) |
|
1,085 (1) |
|
1,197 (1) |
|
1,509 (1) |
|
2,145 (1) |
|
2,365 (1) |
|
|
High |
l/h |
|
671 (1) |
|
1,059 (1) |
|
1,344 (1) |
|
1,501 (1) |
|
2,163 (1) |
|
2,953 (1) |
|
3,270 (1) |
|
Heating |
High |
l/h |
|
705 (2) |
|
1,114 (2) |
|
1,369 (2) |
|
1,551 (2) |
|
2,209 (2) |
|
3,008 (2) |
|
3,311 (2) |
|
|
Low |
l/h |
|
529 (2) |
|
972 (2) |
|
1,124 (2) |
|
1,264 (2) |
|
1,573 (2) |
|
2,203 (2) |
|
2,389 (2) |
|
Water pressure drop |
Heating |
High |
kPa |
|
15 (2) |
|
22 (2) |
|
21 (2) |
|
14 (2) |
|
25 (2) |
|
31 (2) |
|
41 (2) |
|
|
|
Low |
kPa |
|
9 (2) |
|
17 (2) |
|
15 (2) |
|
10 (2) |
|
14 (2) |
|
18 (2) |
|
23 (2) |
|
|
Cooling |
High |
kPa |
|
17 (1) |
|
24 (1) |
|
24 (1) |
|
16 (1) |
|
29 (1) |
|
37 (1) |
|
48 (1) |
|
|
|
Low |
kPa |
|
10 (1) |
|
18 (1) |
|
17 (1) |
|
11 (1) |
|
15 (1) |
|
21 (1) |
|
27 (1) |
|
|
Nom. |
l/h |
674 |
|
1,064 |
|
1,339 |
|
1,514 |
|
2,056 |
|
2,833 |
|
3,140 |
|
|
Heating |
Nom. |
l/h |
674 |
|
1,064 |
|
1,339 |
|
1,514 |
|
2,056 |
|
2,833 |
|
3,140 |
|
Fan motor |
Model |
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
Closed induction, B class insulation, winding thermal cut-out |
|
|
Speed |
Steps |
3 (high, medium, low) |
|
3 (high, medium, low) |
|
3 (high, medium, low) |
|
3 (high, medium, low) |
|
3 (high, medium, low) |
|
3 (high, medium, low) |
|
3 (high, medium, low) |
|
Cooling capacity |
Total capacity |
High |
kW |
3.90 (1) |
|
6.20 (1) |
|
7.80 (1) |
|
8.82 (1) |
|
11.90 (1) |
|
16.40 (1) |
|
18.30 (1) |
|
|
Sensible capacity |
High |
kW |
3.08 (1) |
|
4.65 (1) |
|
6.52 (1) |
|
7.16 (1) |
|
9.36 (1) |
|
12.80 (1) |
|
14.10 (1) |
|
Heat exchanger |
Water volume |
l |
1.06 |
|
1.42 |
|
1.79 |
|
2.38 |
|
2.5 |
|
4.02 |
|
5.03 |
|
|
Rows |
Quantity |
3 |
|
3 |
|
3 |
|
4 |
|
3 |
|
4 |
|
5 |
|
|
Face area |
m² |
0.138 |
|
0.190 |
|
0.243 |
|
0.243 |
|
0.340 |
|
0.414 |
|
0.414 |
|
|
Fin pitch |
Mm |
2.1 |
|
1.8 |
|
2.1 |
|
2.1 |
|
2.1 |
|
2.1 |
|
2.1 |
|
|
Stages |
Quantity |
10 |
|
10 |
|
10 |
|
10 |
|
14 |
|
14 |
|
14 |
|
Piping connections |
Drain |
OD |
Mm |
16 |
17 |
16 |
17 |
16 |
17 |
16 |
17 |
16 |
17 |
16 |
17 |
16 |
17 |
Power input |
High |
kW |
|
0.265 |
|
0.460 |
|
0.505 |
|
0.505 |
|
0.750 |
|
1.300 |
|
1.300 |
|
Low |
kW |
|
0.14 |
|
0.35 |
|
0.29 |
|
0.29 |
|
0.37 |
|
0.87 |
|
0.87 |
|
Nom. |
W |
173 |
|
294 |
|
336 |
|
336 |
|
473 |
|
966 |
|
966 |
|
|
Low |
W |
130 |
|
247 |
|
261 |
|
261 |
|
328 |
|
704 |
|
704 |
|
|
High |
W |
234 |
|
349 |
|
443 |
|
443 |
|
714 |
|
1,197 |
|
1,197 |
|
Sound power level |
High |
dBA |
66 |
|
69 |
|
72 |
|
72 |
|
74 |
|
78 |
|
78 |
|
|
Low |
dBA |
54 |
|
59 |
|
62 |
|
62 |
|
60 |
|
69 |
|
69 |
|
|
Nom. |
dBA |
61 |
|
63 |
|
67 |
|
67 |
|
67 |
|
73 |
|
73 |
|
Air filter |
Type |
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Acrylic - Filtering class EU2 |
|
Dimensions |
Unit |
Width |
Mm |
754 |
754 |
964 |
964 |
1,174 |
1,170 |
1,174 |
1,170 |
1,174 |
1,170 |
1,384 |
1,380 |
1,384 |
1,380 |
|
|
Depth |
Mm |
559 |
280 |
559 |
280 |
559 |
280 |
559 |
280 |
718 |
353 |
718 |
353 |
718 |
353 |
|
|
Height |
Mm |
280 |
559 |
280 |
559 |
280 |
559 |
280 |
559 |
352 |
718 |
352 |
718 |
352 |
718 |
Water connections |
Additional coil |
inch |
|
|
|
|
|
|
|
|
|
|
|
|
|
1/2" |
|
Primary coil |
inch |
|
3/4 " |
|
3/4 " |
|
3/4 " |
|
3/4 " |
|
1/2" |
|
1/2" |
|
1/2" |
|
Std. heat exchanger |
inch |
3/4 |
|
3/4 |
|
3/4 |
|
3/4 |
|
1 |
|
1 |
|
1 |
|
Casing |
Colour |
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Galvanised sheet metal |
|
Weight |
Unit |
kg |
33 |
32.5 |
41 |
40.6 |
47 |
47.3 |
49 |
48.7 |
65 |
65.3 |
77 |
77.0 |
80 |
79.5 |
Fan |
Air flow rate |
High |
m³/h |
800 |
|
1,250 |
|
1,600 |
|
1,600 |
|
2,200 |
|
3,000 |
|
3,000 |
|
|
Available static pressure |
High |
Pa |
|
67 |
|
59 |
|
67 |
|
66 |
|
78 |
|
76 |
|
74 |
|
|
Low |
Pa |
|
38 |
|
41 |
|
38 |
|
38 |
|
30 |
|
31 |
|
32 |
|
Type |
1 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
|
Available pressure |
High |
Pa |
66 |
|
58 |
|
68 |
|
64 |
|
97 |
|
145 |
|
134 |
|
Cooling capacity (standard conditions) |
Sensible capacity 2-pipe |
Low |
kW |
|
2.10 (1) |
|
3.66 (1) |
|
4.84 (1) |
|
5.23 (1) |
|
6.35 (1) |
|
8.61 (1) |
|
9.37 (1) |
|
|
High |
kW |
|
2.83 (1) |
|
4.16 (1) |
|
6.04 (1) |
|
6.58 (1) |
|
9.22 (1) |
|
12.21 (1) |
|
13.49 (1) |
|
Total capacity 2-pipe |
Low |
kW |
|
2.74 (1) |
|
4.99 (1) |
|
6.03 (1) |
|
6.68 (1) |
|
8.42 (1) |
|
11.63 (1) |
|
12.92 (1) |
|
|
High |
kW |
|
3.65 (1) |
|
5.71 (1) |
|
7.33 (1) |
|
8.25 (1) |
|
11.86 (1) |
|
15.92 (1) |
|
17.74 (1) |
Heating capacity |
2-Pipe |
High |
kW |
4.05 (2) |
|
7.71 (2) |
|
9.43 (2) |
|
10.79 (2) |
|
14.45 (2) |
|
19.81 (2) |
|
21.92 (2) |
|
Heating capacity (standard conditions) |
Capacity 2-pipe |
High |
kW |
|
4.05 (2) |
|
6.42 (2) |
|
7.88 (2) |
|
8.93 (2) |
|
12.72 (2) |
|
17.29 (2) |
|
19.05 (2) |
|
|
Low |
kW |
|
3.04 (2) |
|
5.59 (2) |
|
6.47 (2) |
|
7.28 (2) |
|
9.06 (2) |
|
12.68 (2) |
|
13.73 (2) |
Vibration insulation |
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Class 1 self-extinguishing |
|
Current input |
Medium |
A |
0.74 |
|
1.39 |
|
1.52 |
|
1.52 |
|
2.08 |
|
4.38 |
|
4.38 |
|
|
High |
A |
0.95 |
|
1.58 |
|
1.97 |
|
1.97 |
|
3.21 |
|
5.37 |
|
5.37 |
|
|
Low |
A |
0.57 |
|
1.18 |
|
1.20 |
|
1.20 |
|
1.50 |
|
3.26 |
|
3.26 |
|
Required wire section |
mm² |
1 |
|
1 |
|
1.5 |
|
1.5 |
|
2 |
|
2.5 |
|
2.5 |
|
Required fuses |
A |
2 |
|
2 |
|
2 |
|
4 |
|
4 |
|
6 |
|
6 |
|
Power supply |
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Voltage |
V |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
|
Phase |
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
Notes |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C at nominal air flow and ESP |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. |
|
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow as in cooling mode at nominal air flow and ESP |
(2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. |
|
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
Maximum Power input at 0Pa ESP |
(3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. |
|
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
Sound level at 0Pa ESP |
(4) - Sound power level according to ISO3741 |
|
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Current input at 0Pa ESP |
(5) - The sound pressure level is measured via a microphone at 1m distance of the unit. |
Power supply |
Type |
|
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
230 / 1 / 50 |
|
Phase |
|
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |
|
1~ |