Specifications Table for FWP-CFN

FWP04CAFN6V3 FWP05CAFN6V3 FWP06CAFN6V3 FWP08CAFN6V3 FWP10CAFN6V3 FWP11CAFN6V3 FWP15CAFN6V3 FWP17CAFN6V3
Cooling capacity (standard conditions) Sensible capacity 4-pipe Low kW 0.62 (1) 0.90 (1) 1.09 (1) 1.47 (1) 1.67 (1) 1.77 (1) 4.64 (1) 4.96 (1)
    High kW 1.36 (1) 1.64 (1) 2.09 (1) 2.89 (1) 3.48 (1) 3.74 (1) 5.46 (1) 5.84 (1)
  Total capacity 4-pipe Low kW 0.93 (1) 1.28 (1) 1.59 (1) 1.95 (1) 2.29 (1) 2.51 (1) 6.28 (1) 7.04 (1)
    High kW 1.91 (1) 2.31 (1) 2.01 (1) 3.75 (1) 4.72 (1) 5.32 (1) 7.38 (1) 8.28 (1)
Heating capacity (standard conditions) Capacity 4-pipe Low kW 1.14 (3) 1.55 (3) 2.09 (1) 2.80 (1) 3.40 (1) 3.40 (1) 6.42 (1) 6.42 (1)
    High kW 2.06 (3) 2.32 (3) 3.29 (1) 4.24 (1) 5.45 (1) 5.45 (1) 7.06 (1) 7.06 (1)
Power input Low kW 0.006 0.010 0.010 0.021 0.011 0.011 0.105 0.105
  High kW 0.032 0.039 0.035 0.077 0.067 0.067 0.162 0.162
Dimensions Unit Height mm 250 250 250 250 280 280 280 280
    Width mm 758 758 968 968 1,178 1,178 1,178 1,178
    Depth mm 665 665 665 665 745 745 745 745
Weight Unit kg 25.8 26.8 34.6 37.6 47.5 47.5 53.5 53.5
Fan Air flow rate Low m³/h 109 170 195 302 333 333 1,050 1,050
    High m³/h 270 336 398 642 755 755 1,289 1,289
  Available static pressure Low Pa 10 19 19 17 12 12 40 40
    High Pa 63 77 63 75 61 61 60 60
Total sound power level Low dBA 28.0 (4) 39.0 (4) 39.0 (4) 38.0 (4) 38.0 (4) 38.0 (4) 61.0 (4) 61.0 (4)
  High dBA 52.0 (4) 54.0 (4) 54.0 (4) 58.0 (4) 58.0 (4) 58.0 (4) 69.0 (4) 69.0 (4)
Sound pressure level Low dBA 20.0 (5) 31.0 (5) 31.0 (5) 30.0 (5) 30.0 (5) 30.0 (5) 53.0 (5) 53.0 (5)
  High dBA 44.0 (5) 46.0 (5) 46.0 (5) 50.0 (5) 50.0 (5) 50.0 (5) 61.0 (5) 61.0 (5)
Water flow Cooling Low l/h 161 (1) 221 (1) 274 (1) 339 (1) 394 (1) 432 (1) 1,094 (1) 1,225 (1)
    High l/h 333 (1) 404 (1) 522 (1) 656 (1) 822 (1) 925 (1) 1,295 (1) 1,448 (1)
  Heating High l/h 180 (3) 204 (3) 288 (3) 371 (3) 477 (3) 477 (3) 618 (3) 618 (3)
    Low l/h 100 (3) 136 (3) 183 (3) 245 (3) 297 (3) 297 (3) 592 (3) 592 (3)
  Water pressure drop Cooling Low kPa 2 (1) 3 (1) 3 (1) 3 (1) 2 (1) 3 (1) 13 (1) 20 (1)
      High kPa 6 (1) 8 (1) 9 (1) 11 (1) 8 (1) 12 (1) 18 (1) 26 (1)
    Heating Low kPa 1 (3) 2 (3) 2 (3) 3 (3) 6 (3) 6 (3) 19 (3) 19 (3)
      High kPa 3 (3) 3 (3) 4 (3) 6 (3) 14 (3) 14 (3) 22 (3) 22 (3)
Allowed water temperature Cooling Min. °C 5 5 5 5 5 5 5 5
  Heating Max. °C 80.000 80.000 80.000 80.000 80.000 80.000 80.000 80.000
Piping connections Water Inlet   1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4"
    Outlet   1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4"
  Drain OD mm 17 17 17 17 17 17 17 17
Water connections Primary coil inch 1/2" 1/2" 1/2" 1/2" 3/4 " 3/4 " 3/4 " 3/4 "
  Additional coil inch 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"
Power supply Type   230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
  Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50 50
  Voltage V 230 230 230 230 230 230 230 230
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.
  (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.
  (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K.
  (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741
  (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit. (5) - The sound pressure level is measured via a microphone at 1m distance of the unit.