FXCQ20AVEB |
FXCQ25AVEB |
FXCQ32AVEB |
FXCQ40AVEB |
FXCQ50AVEB |
FXCQ63AVEB |
FXCQ80AVEB |
FXCQ125AVEB |
Cooling capacity |
Total capacity |
At high fan speed |
kW |
2.2 (1) |
2.8 (1) |
3.6 (1) |
4.5 (1) |
5.6 (1) |
7.1 (1) |
9.0 (1) |
14.0 (1) |
Heating capacity |
Total capacity |
At high fan speed |
kW |
2.5 (2) |
3.2 (2) |
4.0 (2) |
5.0 (2) |
6.3 (2) |
8.0 (2) |
10.0 (2) |
16.0 (2) |
Power input - 50Hz |
Cooling |
At high fan speed |
kW |
0.031 |
0.039 |
0.039 |
0.041 |
0.059 |
0.063 |
0.090 |
0.149 |
|
Heating |
At high fan speed |
kW |
0.028 |
0.035 |
0.035 |
0.037 |
0.056 |
0.060 |
0.086 |
0.146 |
Dimensions |
Unit |
Height |
mm |
305 |
305 |
305 |
305 |
305 |
305 |
305 |
305 |
|
|
Width |
mm |
775 |
775 |
775 |
775 |
990 |
990 |
1,445 |
1,445 |
|
|
Depth |
mm |
620 |
620 |
620 |
620 |
620 |
620 |
620 |
620 |
Weight |
Unit |
kg |
19 |
19 |
19 |
19 |
22 |
25 |
33 |
38 |
Casing |
Material |
|
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Galvanised steel plate |
Fan |
Air flow rate - 50Hz |
Cooling |
At high fan speed |
m³/min |
10.5 |
11.5 |
11.5 |
12 |
15 |
16 |
26 |
32 |
|
|
|
At low fan speed |
m³/min |
7.5 |
8 |
8 |
8.5 |
10.5 |
11.5 |
18.5 |
22.5 |
Refrigerant |
Type |
|
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
R-410A |
|
GWP |
|
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
2,087.5 |
Sound power level |
Cooling |
At high fan speed |
dBA |
48 |
50 |
50 |
52 |
53 |
55 |
58 |
62 |
Sound pressure level |
Cooling |
At high fan speed |
dBA |
32.0 |
34.0 |
34.0 |
36.0 |
37.0 |
39.0 |
42.0 |
46.0 |
|
|
At medium fan speed |
dBA |
30.0 |
31.0 |
32.0 |
33.0 |
35.0 |
37.0 |
38.0 |
42.0 |
|
|
At low fan speed |
dBA |
28.0 |
29.0 |
30.0 |
31.0 |
31.0 |
32.0 |
33.0 |
38.0 |
|
Heating |
At high fan speed |
dBA |
32.0 |
34.0 |
34.0 |
36.0 |
37.0 |
39.0 |
42.0 |
46.0 |
|
|
At medium fan speed |
dBA |
30.0 |
31.0 |
32.0 |
33.0 |
35.0 |
37.0 |
38.0 |
42.0 |
|
|
At low fan speed |
dBA |
28.0 |
29.0 |
30.0 |
31.0 |
31.0 |
32.0 |
33.0 |
38.0 |
Piping connections |
Liquid |
Type |
|
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
|
|
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
9.52 |
9.52 |
9.52 |
|
Gas |
Type |
|
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
Flare connection |
|
|
OD |
mm |
12.7 |
12.7 |
12.7 |
12.7 |
12.7 |
15.9 |
15.9 |
15.9 |
|
Drain |
|
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
VP25 (O.D. 32 / I.D. 25) |
Decoration panel |
Model |
|
BYBCQ40HW1 |
BYBCQ40HW1 |
BYBCQ40HW1 |
BYBCQ40HW1 |
BYBCQ63HW1 |
BYBCQ63HW1 |
BYBCQ125HW1 |
BYBCQ125HW1 |
|
Colour |
|
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
Fresh white (6.5Y 9.5/0.5) |
|
Dimensions |
Height |
mm |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
|
|
Width |
mm |
1,070 |
1,070 |
1,070 |
1,070 |
1,285 |
1,285 |
1,740 |
1,740 |
|
|
Depth |
mm |
700 |
700 |
700 |
700 |
700 |
700 |
700 |
700 |
|
Weight |
kg |
10 |
10 |
10 |
10 |
11 |
11 |
13 |
13 |
Air filter |
Type |
|
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Resin net with mold resistance |
Power supply |
Name |
|
VE |
VE |
VE |
VE |
VE |
VE |
VE |
VE |
|
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
Current - 50Hz |
Maximum fuse amps (MFA) |
A |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
Notes |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) |
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) |
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. |
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
|
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
(5) - Maximum allowable voltage range variation between phases is 2%. |
|
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
(6) - MCA/MFA: MCA = 1.25 x FLA |
|
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
(7) - MFA ≤ 4 x FLA |
|
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
(8) - Next lower standard fuse rating minimum 16A |
|
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
(9) - Select wire size based on the value of MCA |
|
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
(10) - Instead of a fuse, use a circuit breaker |
|
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |
(11) - Contains fluorinated greenhouse gases |