ATXM25M2V1B / ARXM25M2V1B |
ATXM35M2V1B / ARXM35M2V1B |
ATXM50M2V1B / ARXM50MV1B |
Cooling capacity
|
Min.
|
kW
|
1.3
|
1.4
|
1.7
|
|
Max.
|
kW
|
3.2
|
4.0
|
5.3
|
|
Nom.
|
kW
|
2.5
|
3.40
|
5.02
|
Space cooling
|
SEER
|
|
8.50
|
8.50
|
7.31
|
|
Annual energy consumption
|
kWh/a
|
103
|
140
|
239
|
|
Capacity
|
Pdesign
|
kW
|
2.50
|
3.40
|
5.00
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A++
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
2.40
|
2.50
|
4.60
|
|
SCOP/A
|
|
5.10
|
5.10
|
4.60
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A++
|
|
Annual energy consumption
|
kWh/a
|
659
|
686
|
1,400
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
285
|
416
|
728
|
|
EER
|
|
4.39
|
4.09
|
3.45
|
|
COP
|
|
5.00
|
4.04
|
3.79
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
A
|
Heating capacity
|
Nom.
|
kW
|
2.8
|
4.00
|
5.8
|
|
Min.
|
kW
|
1.3
|
1.4
|
1.7
|
|
Max.
|
kW
|
4.7
|
5.2
|
6.5
|
Notes
|
(1) - EER/COP according to Eurovent 2012, for use outside EU only
|
(1) - EER/COP according to Eurovent 2012, for use outside EU only
|
(1) - EER/COP according to Eurovent 2012, for use outside EU only
|
|
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
|
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
|