| AZQS71B2V1B UK | AZQS100B8V1B UK | AZQS125B8V1B UK | AZQS140B8V1B UK | |||||
|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 50 | 57 | 58 | 54 | |
| Cooling | Nom. | dBA | 48 | 53 | 54 | 53 | ||
| Night quiet mode | Level 1 | dBA | 43 | 49 | 49 | 49 | ||
| Standard Accessories | Tie-wraps | 2 | 2 | 2 | 2 | |||
| Installation manual | 1 | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 5.7 | 6.1 | 6.1 | 8.4 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 2.75 | 2.9 | 2.9 | 4.0 | |||
| Type | R-410A | R-410A | R-410A | R-410A | ||||
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | 9.52 | 9.52 | |
| Piping length | OU - IU | Max. | m | 30 | 30 | 30 | 30 | |
| System | Chargeless | m | 30 | 30 | 30 | 30 | ||
| Equivalent | m | 40 | 40 | 40 | 40 | |||
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | 15.9 | ||
| Level difference | IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | ||
| IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | 30.0 | ||
| Additional refrigerant charge | kg/m | See installation manual | See installation manual | See installation manual | See installation manual | |||
| Sound power level | Cooling | dBA | 64 | 70 | 71 | 70 | ||
| Dimensions | Unit | Width | mm | 900 | 940 | 940 | 940 | |
| Depth | mm | 320 | 320 | 320 | 320 | |||
| Height | mm | 770 | 990 | 990 | 1,430 | |||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Weight | Unit | kg | 67 | 72.8 | 74.3 | 94.9 | ||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | |||
| Notes | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | ||||
| (2) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||
| (3) - See separate drawing for electrical data | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (4) - Contains fluorinated greenhouse gases | (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 | (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 | (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN 61000-3-2 | |||||
| (5) - See separate drawing for electrical data | (5) - See separate drawing for electrical data | (5) - See separate drawing for electrical data | ||||||
| (6) - Contains fluorinated greenhouse gases | (6) - Contains fluorinated greenhouse gases | (6) - Contains fluorinated greenhouse gases | ||||||
| (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (7) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | ||||||
| (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (8) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | ||||||