EBBH11DF6V |
EBBH16DF6V |
Casing
|
Colour
|
|
White + Black
|
White + Black
|
|
Material
|
|
Resin, sheet metal
|
Resin, sheet metal
|
Dimensions
|
Unit
|
Height
|
mm
|
840
|
840
|
|
|
Width
|
mm
|
440
|
440
|
|
|
Depth
|
mm
|
390
|
390
|
Weight
|
Unit
|
kg
|
52.5
|
54.5
|
PED
|
Category
|
|
Category II
|
Category II
|
Sound power level
|
Nom.
|
dBA
|
44 (3)
|
44
|
Sound pressure level
|
Nom.
|
dBA
|
30 (4)
|
30
|
Operation range
|
Heating
|
Water side
|
Min.
|
°C
|
15 (5)
|
15
|
|
|
|
Max.
|
°C
|
60 (5)
|
60
|
|
Cooling
|
Ambient
|
Min.
|
°CDB
|
10 (5)
|
10
|
|
|
Water side
|
Min.
|
°C
|
5 (5)
|
5
|
|
|
|
Max.
|
°C
|
22 (5)
|
22
|
Power supply
|
Name
|
|
See note 6
|
See note 6
|
Electric heater
|
Power supply
|
Name
|
|
6V3
|
6V3
|
|
|
Phase
|
|
1~ / 3~
|
1~ / 3~
|
|
|
Frequency
|
Hz
|
50
|
50
|
|
|
Voltage
|
V
|
230
|
230
|
|
Recommended fuses
|
A
|
20 (7)
|
20
|
Notes
|
(1) - Operation area is extended to lower flow rates depending on operation mode - refer to ESP curve.
|
(1) - Operation area is extended to lower flow rates depending on operation mode - refer to ESP curve.
|
|
(2) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils)
|
(2) - Excluding the water volume in the unit. This volume will guarantee suficient defrost energy for all applications, however, this volume can be multiplied by 0,66 if the heating sepoint is ≥ 45° C (eg. Fan coils)
|
|
(3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.
|
(3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.
|
|
(4) - Sound values are measured in a semi-anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
(4) - Sound values are measured in a semi-anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
|
(5) - For more details, see operation range drawing
|
(5) - For more details, see operation range drawing
|
|
(6) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram)
|
(6) - 4 pole 20 A curve 400V tripping class C (refer to wiring diagram)
|