Specifications Table for EBLA04-08EV3

EBLA04E2V3 EBLA06E2V3 EBLA08E2V3
Heating capacity Nom. kW 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2)
Cooling capacity Nom. kW 4.86 (1), 4.52 (2) 5.83 (1), 5.09 (2) 6.18 (1), 5.44 (2)
Power input Cooling Nom. kW 0.820 (1), 1.36 (2) 1.08 (1), 1.55 (2) 1.19 (1), 1.73 (2)
  Heating Nom. kW 0.840 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2)
COP 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.91 (1), 3.32 (2) 5.40 (1), 3.28 (2) 5.19 (1), 3.14 (2)
Dimensions Unit Height mm 770 770 770
    Width mm 1250 1250 1250
    Depth mm 362 362 362
Weight Unit kg 88 88 88
Operation range Heating Water side Min. °C 9 (3) 9 (3) 9 (3)
      Max. °C 65 (3) 65 (3) 65 (3)
  Cooling Ambient Min. °CDB 10 (3) 10 (3) 10 (3)
      Max. °CDB 43 43 43
    Water side Min. °C 5 (3) 5 (3) 5 (3)
      Max. °C 22 22 22
  Domestic hot water Ambient Min. °CDB -27 -27 -27
      Max. °CDB 35 35 35
    Water side Min. °C 25 25 25
      Max. °C 55 (3) 55 (3) 55 (3)
Sound power level Heating Nom. dBA 58.0 (1) 60.0 (1) 62.0 (1)
  Cooling Nom. dBA 61.0 (1) 62.0 (1) 62.0 (1)
Sound pressure level Heating Nom. dBA 44.0 (1) 47.0 (1) 49.0 (1)
  Cooling Nom. dBA 48.0 (1) 49.0 (1) 50.0 (1)
Refrigerant Type   R-32 R-32 R-32
  GWP   675 675 675
  Charge kg 1.35 1.35 1.35
  Charge tCO2Eq 0.91 0.91 0.91
Space heating Average climate water outlet 55°C General SCOP   3.29 3.28 3.35
      Seasonal space heating eff. class   A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.54 4.52 4.61
      Seasonal space heating eff. class   A+++ A+++ A+++
Compressor component Main power supply Phase   3N~ 3N~ 3N~
    Voltage V 220 220 220
Power supply Name   V3 V3 V3
  Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 230 +/-10% 230 +/-10% 230 +/-10%
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing