Specifications Table for EBVZ-D9W / ERLA11-14DV3

EBVZ16S18DJ9W / ERLA11DAV3 EBVZ16S23DJ9W / ERLA11DAV3 EBVZ16S18DJ9W / ERLA11D2V3 EBVZ16S23DJ9W / ERLA11D2V3 EBVZ16S18DJ9W / ERLA14DAV3 EBVZ16S23DJ9W / ERLA14DAV3 EBVZ16S18DJ9W / ERLA14D2V3 EBVZ16S23DJ9W / ERLA14D2V3
Heating capacity Nom. kW 10.6 (1), 9.82 (2) 10.6 (1), 9.82 (2) 10.6 (1), 9.82 (2) 10.6 (1), 9.82 (2) 12.0 (1), 12.5 (2) 12.0 (1), 12.5 (2) 12.0 (1), 12.5 (2) 12.0 (1), 12.5 (2)
Power input Heating Nom. kW 2.18 (1), 2.68 (2) 2.18 (1), 2.68 (2) 2.18 (1), 2.68 (2) 2.18 (1), 2.68 (2) 2.46 (1), 3.42 (2) 2.46 (1), 3.42 (2) 2.46 (1), 3.42 (2) 2.46 (1), 3.42 (2)
  Domestic hot water from 10°C to 50°C Nom. kWh 2.44 3.41 2.44 3.41 2.44 3.41 2.44 3.41
Heat up time from 10°C to 50°C hr 1h15min at 7°C ambient temperature 1h07min at 7°C ambient temperature 1h15min at 7°C ambient temperature 1h07min at 7°C ambient temperature 1h15min at 7°C ambient temperature 1h07min at 7°C ambient temperature 1h15min at 7°C ambient temperature 1h07min at 7°C ambient temperature
COP 4.83 (1), 3.66 (2) 4.83 (1), 3.66 (2) 4.83 (1), 3.66 (2) 4.83 (1), 3.66 (2) 4.87 (1), 3.64 (2) 4.87 (1), 3.64 (2) 4.87 (1), 3.64 (2) 4.87 (1), 3.64 (2)
Domestic hot water heating General Declared load profile   L XL L XL L XL L XL
  Average climate Water heating energy efficiency class   A+ A A+ A A+ A A+ A
Space heating Average climate water outlet 55°C General SCOP   3.23 3.23 3.23 3.23 3.22 3.22 3.22 3.22
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.61 4.61 4.61 4.61 4.60 4.60 4.60 4.60
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (3) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.