Specifications Table for EDLA09-14D3W1

EDLA09DA3W1 EDLA11DA3W1 EDLA14DA3W1
Heating capacity Nom. kW 9.37, 9.00 10.6, 9.82 12.0, 12.5
Heater capacity Step 1 kW 3 3 3
Power input Heating Nom. kW 1.91, 2.43 2.18, 2.68 2.46, 3.42
COP 4.91, 3.71 4.83, 3.66 4.87, 3.64
Dimensions Unit Height mm 870 870 870
    Width mm 1380 1380 1380
    Depth mm 460 460 460
Weight Unit kg 149 149 149
Fan Air flow rate Heating High m³/min 48.0 55.8 70.4
Operation range Heating Water side Min. °C 15 15 15
      Max. °C 60 60 60
  Domestic hot water Ambient Min. °CDB -25 -25 -25
      Max. °CDB 35 35 35
    Water side Min. °C 25 25 25
      Max. °C 55 55 55
Refrigerant Type   R-32 R-32 R-32
  GWP   675 675 675
  Charge kg 3.80 3.80 3.80
  Charge tCO2Eq 2.57 2.57 2.57
Space heating Average climate water outlet 55°C General SCOP   3.39 3.32 3.37
      Seasonal space heating eff. class   A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.72 4.64 4.62
      Seasonal space heating eff. class   A+++ A+++ A+++
Compressor component Main power supply Phase   3N~ 3N~ 3N~
    Voltage V 400 400 400
Power supply Name   W1 W1 W1
  Phase   3~ 3~ 3~
  Frequency Hz 50 50 50
  Voltage V 400 400 400
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing (3) - For more details, see operation range drawing
  (4) - Depends on operation mode, refer to installation manual. (4) - Depends on operation mode, refer to installation manual. (4) - Depends on operation mode, refer to installation manual.