| EHSX08P30EF / ERGA06EAV3H | EHSX08P50EF / ERGA06EAV3H | EHSX08P30EG / ERGA06EAV3H | EHSX08P50EG / ERGA06EAV3H | |||||
|---|---|---|---|---|---|---|---|---|
| Indoor unit | EHSX08P30EF | EHSX08P50EF | EHSX08P30EG | EHSX08P50EG | ||||
| Heating capacity | Nom. | kW | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | ||
| Cooling capacity | Nom. | kW | 5.96 (1), 5.09 (2) | 5.96 (1), 5.09 (2) | 5.96 (1), 5.09 (2) | 5.96 (1), 5.09 (2) | ||
| Power input | Heating | Nom. | kW | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | |
| Cooling | Nom. | kW | 1.06 (1), 1.55 (2) | 1.06 (1), 1.55 (2) | 1.06 (1), 1.55 (2) | 1.06 (1), 1.55 (2) | ||
| COP | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | ||||
| EER | 5.61 (1), 3.28 (2) | 5.61 (1), 3.28 (2) | 5.61 (1), 3.28 (2) | 5.61 (1), 3.28 (2) | ||||
| Domestic hot water heating | General | Declared load profile | L | XL | L | XL | ||
| Average climate | Water heating energy efficiency class | A+ | A+ | A+ | A+ | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.28 | 3.28 | 3.28 | 3.28 | |
| Seasonal space heating eff. class | A++ | A++ | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.52 | 4.52 | 4.52 | 4.52 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | ||||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||